Short Tandem Repeats (STRs) are the most widespread markers in forensic genetics. However, STR stutter peaks can mask alleles from a minor contributor when analysing mixtures, hindering the interpretation of complex profiles. In this study we compared the performance of a previously described panel of microhaplotypes (MHs), an alternative type of forensic marker, against a standard STR kit. The parameters evaluated included: capability of determining the minimum number of contributors in the mixture; percentages of allele drop-outs and drop-ins; retrieval of alleles belonging to the minor contributor, and estimation of likelihood ratio (LR) values. In addition, the capacity of EuroForMix software to estimate each donor's percentage of contribution was tested, as well as the impact on results when using manually, or automatically prepared libraries. The MH panel showed better performance than STRs for the detection of 2-contributor mixtures, but the lower degree of polymorphism per MH marker hindered the task of deconvolution with multiple contributors. MHs presented higher drop-in rates and lower drop-out rates, a higher capability to recover the minor contributor's alleles and provided higher LR values than STRs, likely due to the much higher number of loci combined in the panel. Estimations of contributor ratios using EuroForMix showed promising results and marginal differences were found in these values between manually and automatically prepared libraries. Overall, results showed that the mixture detection performance of the MH panel was better or equal to the standard forensic autosomal STR panel, indicating microhaplotypes are informative markers for this purpose.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.fsigen.2024.103144DOI Listing

Publication Analysis

Top Keywords

str panel
8
minor contributor
8
manually automatically
8
automatically prepared
8
prepared libraries
8
panel better
8
panel
7
performance
4
performance comparison
4
comparison validated
4

Similar Publications

Multi-insertion/deletion polymorphisms (Multi-InDels), as the novel genetic markers, show great potential in forensic research. Whereas, forensic researchers mainly focus on the multi-InDels on the autosomes, which can provide relatively limited information in some complex paternity cases. In this study, a novel X chromosomal multi-InDel multiplex amplification system was designed, containing 22 multi-InDels and one STR locus on the X chromosome.

View Article and Find Full Text PDF

RIFM fragrance ingredient safety assessment, geranyl crotonate, CAS Registry Number 56172-46-4.

Food Chem Toxicol

December 2024

Member Expert Panel for Fragrance Safety, The Journal of Dermatological Science (JDS), Department of Dermatology, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu 431-3192, Japan.

View Article and Find Full Text PDF

Update to RIFM fragrance ingredient safety assessment, 2-methyl-4(2,2,3-trimethyl-3-cyclopentenyl)butanol, CAS Registry Number 72089-08-8.

Food Chem Toxicol

December 2024

Member Expert Panel for Fragrance Safety, The Journal of Dermatological Science (JDS), Department of Dermatology, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu 431-3192, Japan.

View Article and Find Full Text PDF

RIFM fragrance ingredient safety assessment, β-pinene, CAS Registry Number 127-91-3.

Food Chem Toxicol

December 2024

Member Expert Panel for Fragrance Safety, The Journal of Dermatological Science (JDS), Department of Dermatology, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu 431-3192, Japan.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!