Purpose: Kilovoltage cone beam computed tomography (kVCBCT)-guided adaptive radiation therapy (ART) uses daily deformed CT (dCT), which is generated automatically through deformable registration methods. These registration methods may perform poorly in reproducing volumes of the target organ, rectum, and bladder during treatment. We analyzed the registration errors between the daily kVCBCTs and corresponding dCTs for these organs using the default optical flow algorithm and two registration procedures. We validated the effectiveness of these registration methods in replicating the geometry for dose calculation on kVCBCT for ART.

Methods: We evaluated three deformable image registration (DIR) methods to assess their registration accuracy and dose calculation effeciency in mapping target and critical organs. The DIR methods include (1) default intensity-based deformable registration, (2) hybrid deformable registration, and (3) a two-step deformable registration process. Each technique was applied to a computerized imaging reference system (CIRS) phantom (Model 062 M) and to five patients who received volumetric modulated arc therapy to the prostate. Registration accuracy was assessed using the 95% Hausdorff distance (HD) and Dice similarity coefficient (DSC), and each method was compared with the intensity-based registration method. The improvement in the dCT image quality of the CIRS phantom and five patients was assessed by comparing dCT with kVCBCT. Image quality quantitative metrics for the phantom included the signal-to-noise ratio (SNR), uniformity, and contrast-to-noise ratio (CNR), whereas those for the patients included the mean absolute error (MAE), mean error, peak signal-to-noise ratio (PSNR), and structural similarity index measure (SSIM). To determine dose metric differences, we used a dose-volume histogram (DVH) and 3.0%/0.3 mm gamma analysis to compare planning computed tomography (pCT) and kVCBCT recalculations with restimulated CT images used as a reference.

Results: The dCT images generated by the hybrid (dCT) and two-step (dCT) registration methods resulted in significant improvements compared to kVCBCT in the phantom model. Specifically, the SNR improved by 107% and 107.2%, the uniformity improved by 90% and 75%, and the CNR improved by 212.2% and 225.6 for dCT and dCT methods, respectively. For the patient images, the MAEs improved by 98% and 94%, the PSNRs improved by 16.3% and 22.9%, and the SSIMs improved by 1% and 1% in the dCT and dCT methods, respectively. For the geometric evaluation, only the two-step registration method improved registration accuracy. The dCT method yielded an average HD of 12 mm and average DSC of 0.73, whereas dCT yielded an average HD of 2.9 mm and average DSC of 0.902. The DVH showed that the dCT-based dose calculations differed by <2% from the expected results for treatment targets and volumes of organs at risk. Additionally, gamma indices for dCT-based treatment plans were >95% at all points, whereas they were <95% for kVCBCT-based treatment plans.

Conclusion: The two-step registration method outperforms the intensity-based and hybrid registration methods. While the hybrid and two-step-based methods improved the image quality of kVCBCT in a linear accelerator, only the two-step method improved the registration accuracy of the corresponding structures among the pCT and kVCBCT datasets. A two-step registration process is recommended for applying kVCBCT to ART, which achieves better registration accuracy for local and global image structures. This method appears to be beneficial for radiotherapy dose calculation in patients with pelvic cancer.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11540054PMC
http://dx.doi.org/10.1002/acm2.14490DOI Listing

Publication Analysis

Top Keywords

registration
16
deformable registration
16
registration methods
16
dct
12
registration accuracy
12
deformable image
8
image registration
8
critical organs
8
computed tomography
8
methods
8

Similar Publications

Trivalent recombinant protein vaccine induces cross-neutralization against XBB lineage and JN.1 subvariants: preclinical and phase 1 clinical trials.

Nat Commun

December 2024

Laboratory of Aging Research and Cancer Drug Target, National Clinical Research Center for Geriatrics, West China Hospital, Sichuan University, Chengdu, China.

The immune escape capacities of XBB variants necessitate the authorization of vaccines with these antigens. In this study, we produce three recombinant trimeric proteins from the RBD sequences of Delta, BA.5, and XBB.

View Article and Find Full Text PDF

Background: Virtual surgical planning (VSP) is an emerging method in head and neck reconstruction with demonstrated benefits, however, its economic viability is supported with mixed evidence.

Methods: A structured search was performed in five electronic databases. Studies that performed an economic evaluation on VSP in head and neck reconstruction were included.

View Article and Find Full Text PDF

Background: Subcutaneous emicizumab, a factor VIII (FVIII)-mimicking bispecific monoclonal antibody, can effectively prevent bleeds in haemophilia A (HA) patients with/without inhibitors; however, its standard-dose regimens are financially burdensome. Low-dose emicizumab prophylaxis may alternatively be applied to noninhibitor HA patients in resource-limited settings.

Methods: During 2023, Thai patients with noninhibitor severe HA or moderate HA with severe bleeding phenotype (historical annualized bleeding rate [ABR] >5 bleeds/year before regular FVIII prophylaxis) who received low-/intermediate-dose FVIII secondary prophylaxis ≥8 months were enrolled.

View Article and Find Full Text PDF

Background: Effective disease management is crucial for rheumatoid arthritis (RA) patients as it can significantly reduce disease-associated symptoms. Currently, the utilization of mobile applications for managing RA patients has gained widespread popularity in clinical settings. However, there is a notable absence of a comprehensive meta-analysis exploring their effectiveness specifically in the context of RA patients.

View Article and Find Full Text PDF

Children's Acceptance of Intraoral Cameras and Smartphones for Caries Detection: A Randomized Controlled Clinical Trial.

Int J Paediatr Dent

December 2024

Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.

Background: Teledentistry can improve access to care, but children's acceptance of different imaging techniques is underexplored.

Aim: The aim of this study was to assess children's acceptance of intraoral cameras and smartphones for caries detection.

Design: A randomized controlled trial was conducted in rural Egyptian nurseries, with children aged ≤ 6 years randomized into intraoral camera or smartphone groups.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!