Case: We present a case of robot-assisted placement of 3 trans-sacral transiliac screws through a single corridor for an unstable U-type sacral fracture in a 95-year-old woman. She had persistent pain and inability to mobilize with physical therapy. At 3-month follow-up, the patient had evidence of interval healing and stable hardware and was able to return to her prior functional baseline.

Conclusion: We demonstrate successful utilization of robotics to place 3 trans-sacral transiliac screws in a single corridor for fixation of an unstable pelvic ring injury. This technique was used to overcome challenges with visualization and implant placement.

Download full-text PDF

Source
http://dx.doi.org/10.2106/JBJS.CC.24.00287DOI Listing

Publication Analysis

Top Keywords

screws single
12
single corridor
12
placement trans-sacral
8
trans-sacral transiliac
8
transiliac screws
8
robotic placement
4
trans-sacral transiiliac
4
transiiliac screws
4
corridor u-type
4
u-type sacrum
4

Similar Publications

Background: Surgical treatment of comminuted and multiple facial fractures is challenging, as identifying the bone anatomy and restoring the alignment are complicated. To overcome the difficulties, 3D-printed "jigsaw puzzle" has been innovated to improve the surgical outcome. This study aimed to demonstrate the feasibility of 3D-printed model in facial fracture restoration procedures.

View Article and Find Full Text PDF

Anatomic Distal Biceps Tendon Repair With All-Suture Cortical Buttons.

Arthrosc Tech

December 2024

Department of Orthopaedic Surgery, University of California Irvine, Orange, California, U.S.A.

Acute, traumatic distal biceps tendon ruptures are a common injury in the middle-aged athletic male population, with direct anatomic surgical repair being the most effective technique to restore maximal strength. Multiple techniques for distal biceps tendon repair have been described, including single- or dual-incision approaches and tendon fixation with cortical buttons, interference screws, suture anchors, and transosseous sutures. In this Technical Note, we demonstrate an anatomic distal biceps tendon repair technique with a single-incision approach using 2 all-suture cortical buttons.

View Article and Find Full Text PDF

Additive manufacturing is an attractive technology due to its versatility in producing parts with diverse properties from a single material. However, the process often generates plastic waste, particularly from failed prints, making sustainability a growing concern. Recycling this waste material presents a potential solution for reducing environmental impact while creating new, functional parts.

View Article and Find Full Text PDF

Spine surgery has undergone significant advancements, particularly with regard to robotic systems that enhance surgical techniques and improve patient outcomes. As these technologies become increasingly integrated into surgical practice, it is essential to evaluate their added value and cost savings. Hence, this study compared robot-assisted and navigation-based spine surgery, focusing on surgical efficiency.

View Article and Find Full Text PDF

Background: Thoracolumbar (TL) fractures are uncommon injuries in the pediatric population. Surgery is recommended for TL fractures with significant deformity, posterior ligamentous complex disruption, or neurological compromise. The Thoracolumbar Injury Classification and Severity Scale (TLICS) has been validated in pediatric populations and serves as a valuable tool for guiding treatment decisions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!