This study aimed to develop a novel internal target volume (ITV) definition for respiratory motion targets, considering target motion velocity and time. The proposed ITV was evaluated in respiratory-gated radiotherapy. An ITV modified with target motion velocity and time (ITVvt) was defined as an ITV that includes a target motion based on target motion velocity and time. The target motion velocity was calculated using four-dimensional computed tomography (4DCT) images. The ITVvts were created from phantom and clinical 4DCT images. The phantom 4DCT images were acquired using a solid phantom that moved with a sinusoidal waveform (peak-to-peak amplitudes of 10 and 20 mm and cycles of 2-6 s). The clinical 4DCT images were obtained from eight lung cancer cases. In respiratory-gated radiotherapy, the ITVvt was compared with conventional ITVs for beam times of 0.5-2 s within the gating window. The conventional ITV was created by adding a uniform margin as the maximum motion within the gating window. In the phantom images, the maximum volume difference between the ITVvt and conventional ITV was -81.9%. In the clinical images, the maximum volume difference was -53.6%. Shorter respiratory cycles and longer BTs resulted in smaller ITVvt compared with the conventional ITV. Therefore, the proposed ITVvt plan could be used to reduce treatment volumes and doses to normal tissues.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12194-024-00837-3DOI Listing

Publication Analysis

Top Keywords

target motion
24
velocity time
16
motion velocity
16
4dct images
16
conventional itv
12
novel internal
8
target
8
internal target
8
target volume
8
motion
8

Similar Publications

Photochromic Sodalites: From Natural Minerals to Advanced Applied Materials.

Acc Chem Res

January 2025

Mineralogical Society of Antwerp, Boterlaarbaan 225, 2100 Deurne, Belgium.

ConspectusWhile photochromic natural sodalites, an aluminosilicate mineral, were originally considered as curiosities, articles published in the past ten years have radically changed this perspective. It has been proven that their artificial synthesis was easy and allowed compositional tuning. Combined with simulations, it has been shown that a wide range of photochromic properties were achievable for synthetic sodalites (color, activation energy, reversibility, etc.

View Article and Find Full Text PDF

Opposite asymmetry in visual perception of humans and macaques.

Curr Biol

January 2025

Department of Psychology, New York University, New York, NY 10003, USA; Center for Neural Science, New York University, New York, NY 10003, USA. Electronic address:

In human adults, visual perception varies throughout the visual field. Performance decreases with eccentricity and varies around polar angle. At isoeccentric locations, performance is typically higher along the horizontal than vertical meridian (horizontal-vertical asymmetry [HVA]) and along the lower than the upper vertical meridian (vertical meridian asymmetry [VMA]).

View Article and Find Full Text PDF

A real-time tumor position prediction based multi-dimensional respiratory motion compensation puncture method.

Phys Med Biol

January 2025

Tianjin University, Centre for advanced Mechanisms and Robotics, Tianjin University, 135 Yaguan Road, Jinnan District, Tianjin, China., Tianjin, 300072, CHINA.

This study proposes a real-time tumor position prediction-based multi-dimensional respiratory motion compensation puncture method to accurately track real-time lung tumors and achieve precise needle puncture. Approach: A hybrid model framework integrating prediction and correlation models is developed to enable real-time tumor localization. A Long Short-Term Memory neural network with bidirectional and attention modules (Bi-LSTM-ATT) is employed for predicting external respiratory signals.

View Article and Find Full Text PDF

Background: Vestibular dysfunction causing imbalance affects c. 80% of acute hospitalized traumatic brain injury (TBI) cases. Poor balance recovery is linked to worse return-to-work rates and reduced longevity.

View Article and Find Full Text PDF

Purpose: This study focused on reducing the margin for prostate cancer treatment using magnetic resonance imaging-guided radiotherapy by investigating the intrafractional motion of the prostate and different motion-mitigation strategies.

Methods: We retrospectively analyzed intrafractional prostate motion in 77 patients with low- to intermediate-risk prostate cancer treated with five fractions of 7.25 Gy on a 1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!