Introduction: Many patients with atrial fibrillation have impaired renal function, and therefore pre-operative CT for radiofrequency catheter ablation should minimize the use of contrast media. This study describes a dual-region-of-interest (D-ROI) protocol for the scanning of pulmonary veins and left atrium (PVs-LA) with less contrast media and optimized scan timing compared to the single-region-of-interest (S-ROI) protocol, without compromising image quality.

Methods: This study retrospectively included 100 patients who underwent PVs-LA CT between July 2019 and February 2022. The participants were divided into two groups: Those scanned using the S-ROI method (Group A, n = 50), and those scanned using the D-ROI method (Group B, n = 50). Descriptive statistical analysis of the contrast effect and scan timing was performed using quantitative and qualitative data collected from both groups of images.

Results: The contrast media dose was larger in group A than in group B (63.6 ± 10.1 mL vs. 45.6 ± 6.9 mL; p < 0.001). The CT values of the PVs-LA did not differ significantly between groups A and B [434.2 ± 77.0 Hounsfield units (HU) and 428.8 ± 77.2 HU, respectively; p = 0.73]. Two evaluators determined appropriate scan timing (when PVs-LA reached a relatively sufficient contrast effect for diagnosis) in 23 (46%) and 45 (90%) patients from groups A and B, respectively (p < 0.001).

Conclusions: Although the radiation dose is slightly increased compared with the S-ROI method, the D-ROI method provides improved scan timing and images with similar contrast enhancement while reducing the amount of contrast medium administered.

Implications For Practice: The novel D-ROI bolus tracking technique can reduce the contrast medium dose while optimizing scan timing.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radi.2024.08.016DOI Listing

Publication Analysis

Top Keywords

contrast media
16
atrial fibrillation
8
scan timing
8
method group
8
group n = 50
8
protocol contrast
4
media
4
media reduction
4
reduction atrial
4
fibrillation ablation-planning
4

Similar Publications

Evaluation of endothelialization of an occluder device with cardiac computed tomography and assessment of the pathological validation.

PLoS One

January 2025

Department of Structural Heart Disease, Cardiovascular Institute and Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

Background: Assessing the endothelialization of occlusive devices noninvasively remains a challenge. Cardiac computed tomography angiography (CTA) can be employed to evaluate device endothelialization based on contrast uptake within the occluder.

Objective: This study examined device endothelialization using cardiac CTA and investigated the pathological associations.

View Article and Find Full Text PDF

Objective: To examine the diagnostic efficacy of contrast-enhanced ultrasound (CEUS) with Sonazoid (Sonazoid-CEUS) for endometrial lesions.

Methods: In this prospective and multicenter study, data were collected from 84 patients with endometrial lesions from 11 hospitals in China. All the patients received a conventional US and Sonazoid-CEUS examination.

View Article and Find Full Text PDF

Background: We examined chronic gadolinium retention impact on gene expression in the mouse central nervous system (CNS) after injection of linear or macrocyclic gadolinium-based contrast agents (GBCAs).

Methods: From 05/2022 to 07/2023, 36 female mice underwent weekly intraperitoneal injections of gadodiamide (2.5 mmol/kg, linear), gadobutrol (2.

View Article and Find Full Text PDF

Introduction Neck manipulations, including massages and self-cracking, are common practices, yet public awareness of their potential risks is poorly understood. This study explores public knowledge and awareness of the risks associated with neck manipulations in the Southern region of Saudi Arabia. Methods The study employed a descriptive cross-sectional design from May 2024 to July 2024, distributing a questionnaire to the adult population in the Southern Region.

View Article and Find Full Text PDF

Background: The incidence of contrast-induced acute kidney injury (CI-AKI) in the general population ranges from 0.6 to 2.3%, whereas for specific high-risk patients, the incidence can reach more than 30-40%.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!