The diagnostic value of the fluorescent immunosorbent test for IgG gliadin antibodies (FIST) has been investigated in comparison with the LIF test--the competence of the gluten subfractions B2 and B3 in releasing lymphokines from peripheral lymphocytes in vitro--in 96 patients with coeliac disease (CD) under various dietary conditions. In untreated children with CD during their first 2 years of life, the FIST showed 100% sensitivity with 95% specificity, whilst the LIF test showed only 70% sensitivity and 73% specificity. Therefore it can be concluded that the FIST as a screening test is superior to the LIF. In older children with a proved recurrence of the mucosal abnormality after reintroduction of a normal diet, only 44% showed increased IgG gliadin antibody titres whereas 70% proved to be positive in the LIF test. Under a controlled gluten challenge all six patients reacted with a distinct increase in gliadin antibody titres whereas the LIF test changed from positive to negative and vice versa without following any clear principle. These results emphasize the inadequacy of the LIF test as a diagnostic method, both in untreated CD and under controlled gluten challenge.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/BF00491928 | DOI Listing |
Sci Rep
December 2024
Nuclear Engineering Unit, Ben-Gurion University of the Negev, Beer-Sheva, Israel.
This study proposes a novel, highly sensitive neutron detector design utilizing a unique multi-layered configuration. Each layer consists of a LiF: ZnS(Ag) scintillator coupled with a transparent neutron moderator that also functions as a light guide for the Silicon Photomultiplier (SiPM) light sensor. This design offers a cost-effective and readily available alternative for existing neutron detectors.
View Article and Find Full Text PDFAdv Mater
December 2024
Department of Chemistry, Pohang University of Science and Technology (POSTECH), 37673, Pohang, Republic of Korea.
Water is pursued as an electrolyte solvent for its non-flammable nature compared to traditional organic solvents, yet its narrow electrochemical stability window (ESW) limits its performance. Solvation chemistry design is widely adopted as the key to suppress the reactivity of water, thereby expanding the ESW. In this study, an acetamide-based ternary eutectic electrolyte achieved an ESW ranging from 1.
View Article and Find Full Text PDFAdv Mater
December 2024
School of Advanced Materials, Peking University Shenzhen Graduate School, Shenzhen, 518055, China.
Single-crystal high-nickel oxide with an integral structure can prevent intergranular cracks and the associated detrimental reactions. Yet, its low surface-to-volume ratio makes surficial degradation a more critical factor in electrochemical performance. Herein, artificial proton-rich (ammonium bicarbonate) shell is successfully introduced on the nickel-rich LiNiCoMnO single crystals for in situ electrochemically conversing into inorganic maskant to enhance stability of cathode.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
December 2024
Program of Materials Science and Engineering, University of California, San Diego, La Jolla, CA 92093, USA.
The concept of employing highly concentrated electrolytes has been widely incorporated into electrolyte design, due to their enhanced Li-metal passivation and oxidative stability compared to their diluted counterparts. However, issues such as high viscosity and sub-optimal wettability, compromise their suitability for commercialization. In this study, we present a highly concentrated dimethyl ether-based electrolyte that appears as a liquid phase at ambient conditions via Li - solvents ion-dipole interactions (Coulombic condensation).
View Article and Find Full Text PDFGenes (Basel)
October 2024
Joint International Research Laboratory of Agriculture and Agri-Product Safety, Ministry of Education of China, Yangzhou University, Yangzhou 225009, China.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!