The fluctuating reproducibility of scientific reports presents a well-recognised issue, frequently stemming from insufficient standardisation, transparency and a lack of information in scientific publications. Consequently, the incorporation of newly developed synthetic methods into practical applications often occurs at a slow rate. In recent years, various efforts have been made to analyse the sensitivity of chemical methodologies and the variation in quantitative outcome observed across different laboratory environments. For today's chemists, determining the key factors that really matter for a reaction's outcome from all the different aspects of chemical methodology can be a challenging task. In response, we provide a detailed examination and customised recommendations surrounding the sensitivity screen, offering a comprehensive assessment of various strategies and exploring their diverse applications by research groups to improve the practicality of their methodologies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11382186PMC
http://dx.doi.org/10.1039/d4sc03017fDOI Listing

Publication Analysis

Top Keywords

improving reproducibility
4
reproducibility condition-based
4
condition-based sensitivity
4
sensitivity assessments
4
assessments application
4
application advancement
4
advancement prospect
4
prospect fluctuating
4
fluctuating reproducibility
4
reproducibility scientific
4

Similar Publications

Measurement of Blood Pressure in Children and Adolescents Outside the Office for the Diagnosis of Hypertension.

Curr Cardiol Rep

January 2025

Section of Pediatric Nephrology, Department of Pediatrics, Yale University School of Medicine, New Haven, USA.

Purpose Of Review: To review the benefits of ambulatory blood pressure monitoring and home blood pressure monitoring in children and to discuss implementation of guideline-recommended ambulatory blood pressure monitoring.

Recent Findings: Compared with office blood pressure, ambulatory blood pressure monitoring and home blood pressure monitoring provide superior accuracy, reproducibility, and stronger associations with target organ damage although future work is needed to determine the utility of home blood pressure monitoring to predict hypertension status on ambulatory blood pressure monitoring. Due to the benefits of out-of-office blood pressure measurement, ambulatory blood pressure monitoring has been recommended to confirm the diagnosis of hypertension in children and adolescents since publication of the 2017 American Academy of Pediatrics clinical practice guidelines on hypertension.

View Article and Find Full Text PDF

Circulating tumor DNA (ctDNA) levels can help predict outcomes in diffuse large B-cell lymphoma (DLBCL), but its integration with DLBCL molecular clusters remains unexplored. Using the LymphGen tool in 77 DLBCL with both ctDNA and tissue biopsy, a 95.8% concordance rate in molecular cluster assignment was observed, showing the reproducibility of molecular clustering on ctDNA.

View Article and Find Full Text PDF

Assessment Implementation Measures (AIM): The Journey Towards the Tool Validity.

J Coll Physicians Surg Pak

January 2025

Department of Oral and Maxillofacial Surgery, Frontier Medical and Dental College, Abbottabad, Pakistan.

Objective: To establish the construct validity of the Assessment Implementation Measures (AIM) tool to accurately assess faculty perspectives on implemented assessment systems, facilitating the alignment with set standards.

Study Design: Qualitative Study. Place and Duration of the Study: The study was carried out at RIPHAH International University and data were collected from participants (senior faculty members) involved in teaching and assessment of undergraduates from various medical and dental colleges in Pakistan.

View Article and Find Full Text PDF

An innovative magnetic immunoassay was developed for the voltammetric detection of carbohydrate antigen-125 (CA-125) on a home-made microfluidic device including a multisyringe pump, selection valve and magneto-controlled detection cell. Two kinds of biofunctionalized nanostructures including anti-CA-125 capture antibody-conjugated magnetic beads and anti-CA-125 detection antibody-labeled silver-polypyrrole (Ag-PPy) nanohybrids were utilized for a sandwiched immunoreaction in the presence of CA-125. With the help of an external magnet, the formed magnetic immunocomplexes were attached to the sensing interface to activate the electrical contact between Ag-PPy nanohybrids and the base electrode, thus resulting in the switching on of the sensor circuit for the generation of voltammetric signals thanks to electroactive Ag-PPy nanohybrids.

View Article and Find Full Text PDF

In clinical movement biomechanics, kinematic measurements are collected to characterise the motion of articulating joints and investigate how different factors influence movement patterns. Representative time-series signals are calculated to encapsulate (complex and multidimensional) kinematic datasets succinctly. Exacerbated by numerous difficulties to consistently define joint coordinate frames, the influence of local frame orientation and position on the characteristics of the resultant kinematic signals has been previously proven to be a major limitation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!