AI Article Synopsis

  • - Patients with X-linked incomplete partition type III (IP3) deafness using cochlear implants experienced higher levels of stimulation and more electrode deactivations over time compared to those with normal hearing anatomy.
  • - The study found that MCL levels increased annually in IP3 patients, while electrode deactivation was common, potentially affecting up to 25% of electrodes by age 15, and impairment in speech perception was linked to these deactivations.
  • - The findings suggest that IP3 patients face a greater risk of cochlear implant issues and declining speech comprehension as they age, indicating a need for better guidance and counseling for families regarding these risks.

Article Abstract

Objectives: Patients with X-linked incomplete partition type III (IP3) deafness treated with cochlear implants exhibit higher "Most Comfortable Loudness" (MCL) levels of stimulation and more electrode deactivation than patients with normal morphology. We endeavored to analyze the progression of the MCL levels and electrode deactivation over time and assess those factors that could have led to deactivation. Furthermore, we aimed to assess whether speech perception was affected by a progressive loss of neural contact.

Design: All 13 patients with the IP3 malformation in our clinical database were analyzed retrospectively with regard to impedance, stimulation levels, deactivated electrodes, and speech perception. A control group of patients with normal anatomy was included.

Results: MCL levels increased over time by 2.5 charge units (qu) per year, which was not seen in the control group. Electrode deactivation was more common in IP3 malformation, and it was estimated that 25% of electrodes would be deactivated by 15 years of age. Impedance was stable but higher in the study population. Speech perception was lower in IP3 malformation generally and was correlated to the number of deactivated electrodes.

Conclusions: Patients diagnosed with IP3 malformation deafness may suffer a greater risk of cochlear implant discontinuation compared with those with normal anatomy. A progressive loss of sensitivity to electrical stimulation may indicate a form of neural degradation in the abnormal cochlea. With time, patients in this group, even with cochlear implant technology, may experience gradual deterioration of speech perception. This has clinical implications for the counseling of parents.

Download full-text PDF

Source
http://dx.doi.org/10.1097/AUD.0000000000001584DOI Listing

Publication Analysis

Top Keywords

speech perception
16
ip3 malformation
16
progressive loss
12
mcl levels
12
electrode deactivation
12
loss sensitivity
8
sensitivity electrical
8
electrical stimulation
8
x-linked incomplete
8
incomplete partition
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!