Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To compare differences in the foveal avascular zone (FAZ) area, measured in the Superficial Vascular Complex (SVC), Deep Vascular Complex (DVC) and a combined analysis of both (SDVC), using two Spectral Domain OCT angiography (OCT-A) protocols, High Speed (HS) and High Resolution (HR).
Methods: A total of 26 eyes of diabetic patients, with and without macular oedema, were examined with two different fovea centered OCT-A volume scans. The two protocols were HS and HR volume scans, and the foveal avascular zone was manually measured in the SVC, DVC, and SDVC slabs by two masked investigators. Inter and intraoperator variability was analysed using Intraclass Correlation Coefficient (ICC) and differences were compared between the HR and HS acquisitions throughout the different vascular slabs.
Results: Intraoperator variability was low in all slabs (ICC > 0.9) and interoperator variability was lower for HR (ICC 0.835-0.911) compared to HS (ICC between 0.604 and 0.865). Comparing HS and HR measurements for the same slab, the correlation was only moderate in SVC and DVC (ICC was 0.640 and 0.568 respectively) but was good in the SDVC (ICC = 0.823). FAZ area measurement in SDVC also showed the smallest bias (mean difference 0.009 mm) and the narrowest limits of agreement (-0.175 to 0.193 mm).
Conclusions: Even in cases of diabetic macular oedema, when measuring the FAZ area, the reproducibility was better between HS and HR protocols when using the SDVC slab, compared to the SVC or DVC slabs alone. Further studies should evaluate the use of the combined SDVC slab for the FAZ assessment, compared to the SVC and DVC slabs alone, in the detection and progression of different retinal diseases.