Objective: Foreign body ingestion is an increasingly prevalent issue for children who are in the preverbal to early verbal stages of life. Foreign bodies lodged in the gastrointestinal tract can cause issues such as obstruction, perforation, and fistulae. Radiographic imaging can often locate most foreign bodies; however, radiolucent objects may be missed. Ultrasound is an alternative imaging modality that can be used to locate and track foreign objects as they pass through the bowel. The objective of this study was to characterize the sonographic appearance of various ingested foreign bodies of varying characteristics in an ex vivo gastrointestinal tract segment.

Methods: A GE Logiq 9 ultrasound machine with a linear transducer at a frequency of 15 MHz was used to examine various ingested foreign bodies placed in a segment of pig intestinal tract.

Results: Imaged objects varied in visual appearance from echogenicity, texture, size, and shape; acoustic shadows and reverberation artifacts cast were particularly distinguishing characteristics.

Conclusions: Ultrasound evaluation to assess foreign body ingestion in the pediatric population may provide a useful alternative or supportive imaging modality in confirming the location and real-time tracking of the ingested item. This may be especially useful for objects of varying radiodensities that cannot always be reliably seen in traditional radiographs.

Download full-text PDF

Source
http://dx.doi.org/10.1097/PEC.0000000000003269DOI Listing

Publication Analysis

Top Keywords

foreign bodies
20
ingested foreign
12
foreign
8
foreign body
8
body ingestion
8
gastrointestinal tract
8
imaging modality
8
bodies
5
ultrasound
4
ultrasound imaging
4

Similar Publications

"INSERT-COIN": A PROSPECTIVE STUDY OF COIN INGESTION IN CHILDREN OF SOUTHERN ITALY.

Am J Gastroenterol

December 2024

Pediatric Clinic, Department of Surgical and Biomedical Sciences, University of Perugia, 06123 Perugia, Italy.

Background And Aims: Coins are the most commonly ingested foreign bodies. When they get stuck in the distal esophagus there is no general agreement about the timing of their removal, since some of them may spontaneously migrate into the stomach, no longer requiring removal. We aimed at evaluating the gastric spontaneous passage of esophageal-retained coins, as well as complications.

View Article and Find Full Text PDF

Accidental ingestion of foreign bodies frequently necessitates emergency department visits, with many cases requiring surgical consultation. Although most ingested items pass through the gastrointestinal tract uneventfully, orthodontic components, such as wires, present a specific risk due to their shape and material properties. This report describes a rare case of a 13-year-old male adolescent whose initial presentation suggested ingestion of a chicken bone.

View Article and Find Full Text PDF

Intracardiac migration of inferior vena cava (IVC) filter or stent is a rare but potentially fatal complication of endovascular venous device placement. There is no consensus whether migrated stents should be surgically removed by open cardiac surgery or retrieved by the percutaneous endovascular route and whether an intervention should be performed immediately or expectantly. Herein, we report a 39-year-old female who received emergent left lobe living donor liver transplantation (LDLT) owing to posthepatectomy liver failure.

View Article and Find Full Text PDF

A rare case of intrathoracic Gauzoma.

J Cardiothorac Surg

January 2025

Department of Thoracic Surgery, Kobe City Medical Center General Hospital, 2-1-1 Minatojima-Minamimachi, Chuo-ku, Kobe, 650-0047, Japan.

Background: Gauzoma is a foreign body reactive granuloma which is an extremely rare complication of thoracic surgery. We describe a case of a Gauzoma in which the gauzes were removed by mini-thoracotomy as a less invasive procedure, discovered incidentally after 35 years of follow-up.

Case Presentation: A 51-year-old man was referred to our department for hyperhidrosis treatment, and imaging studies and biopsy confirmed the diagnosis of Gauzoma.

View Article and Find Full Text PDF

Background And Purpose:  This study updates 2 parallel systematic reviews and meta-analyses from 2012, which established the 1-year radiostereometric (RSA) migration thresholds for tibial components of total knee replacements (TKR) based on the risk of late revision for aseptic loosening from survival studies. The primary aim of this study was to determine the (mis)categorization rate of the 2012 thresholds using the updated review as a validation dataset. Secondary aims were evaluation of 6-month migration, mean continuous (1- to 2-year) migration, and fixation-specific thresholds for tibial component migration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!