Objective: To examine one academic institution's experiences with SpaceOAR placement, its associated complications, and periprocedural characteristics that affect outcomes for the purpose of quality improvement.
Materials And Methods: We conducted a retrospective review of 233 patients who received SpaceOAR from four surgeons and one radiation oncologist between 2018 and 2021. Variables such as demographics, oncologic parameters, radiation plan, and radiographic assessment of hydrogel placement were recorded. The Charlson Comorbidity Index (CCI) was used to assess comorbidity risk. Mann-Whitney and Fisher's exact tests were performed to compare patients with and without complications.
Results: Of the 233 patients who received SpaceOAR, 24 (10.3%) experienced toxicity. All complications were Clavien I or II, such as pelvic pain postplacement, pelvic fullness, bleeding, and lower urinary tract symptoms. 16 patients (6.9%) had some portion of the hydrogel injected into the rectal wall, but it was never clinically significant. The average CCI was 3.2 ± 0.95 for patients who experienced complications; the average CCI was 3.6 ± 1.6 (=0.48) in the group without complications. Of the physicians with higher procedure volumes, Physician #1 had the highest rate of patient-reported complications at 11 out of 68 (16.2%) and Physician #2 had the lowest rate of complications at 4 out of 96 placements (4.2%). Multivariate analysis found that patients who had received hormone therapy previously had less odds of reporting complications after SpaceOAR placement.
Conclusions: The listed attending on the procedure had a significant correlation to complications with SpaceOAR placement on univariate analysis, and hormone therapy had some benefits to the tolerance for the procedure on multivariate analysis. Overall, the hydrogel placement was well tolerated with low incidence of mild and transient procedure-related toxicity.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11387085 | PMC |
http://dx.doi.org/10.1155/2024/3439727 | DOI Listing |
Adv Wound Care (New Rochelle)
January 2025
Kenatha Scientific Consulting LLC, Fort Worth, Texas, USA.
SN514 is a thermolysin-like enzyme under development as a debrider. Preclinical and non-clinical studies supported a first in human healthy volunteer study to predict the need for protection of periwound skin. Pharmacologic activity testing compared digestion of collagen, fibrin, and elastin with relevant enzymes.
View Article and Find Full Text PDFInt J Urol
January 2025
Department of Urology, National Cancer Center Hospital East, Kashiwa, Chiba, Japan.
Objectives: This study aimed to investigate the association between the type of prostate biopsy and the occurrence of rectal wall infiltration (RWI) with hydrogel spacer placement in patients undergoing radiotherapy for prostate cancer.
Methods: A retrospective study was conducted involving 175 patients who received hydrogel spacer placement before radiotherapy at the National Cancer Center East Hospital, between October 2021 and December 2023. The patients were categorized based on the type of prostate biopsy: transperineal and transrectal.
3D Print Med
January 2025
Department of Surgical & Interventional Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
Background: Penile implant surgery is the standard surgical treatment for end-stage erectile dysfunction. However, the growing complexity of modern high-tech penile prostheses has increased the demand for more practical training opportunities. The most advanced contemporary training methods involve simulation training using cadavers, with costs exceeding $5,000 per cadaver, inclusive of biohazard fees.
View Article and Find Full Text PDFInt J Pharm
January 2025
Research Institute for Medicine (iMed.ULisboa), Faculty of Pharmacy, Universidade de Lisboa, Lisbon, Portugal. Electronic address:
Prolonged use of Personal Protective Equipment, like surgical masks, can cause skin issues such as acne ("maskne") and rosacea flare-ups due to pressure and moisture. While dressings can protect the skin, they often reduce mask effectiveness and lack pharmaceuticals to treat common skin lesions. This study introduces an innovative dual-function gelatin/tannic acid-based hydrogel patch incorporating metronidazole (1% w/w) or salicylic acid (2% w/w) to offer both skin protection and treatment.
View Article and Find Full Text PDFCureus
December 2024
Orthopaedic Surgery, Maimonides Medical Center, Brooklyn, USA.
Tissue gliding and mobility are paramount to the success of penile procedures. While postoperative healing is intended to protect, repair, and nourish injured tissues, an overzealous response often leaves painful and debilitating tethering between the corpora, including nerves, and surrounding tissues. This tethering interferes with the intended outcomes of surgery by preventing necessary gliding.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!