Introduction: Cerebral venous sinus stenting (CVSS) is an effective treatment for idiopathic intracranial hypertension (IIH) secondary to dural venous sinus stenosis. Traditional selection of patients for CVSS has been made by microcatheter manometry, but pressure measurements are often equivocal. Here we present the results of a series of cases in which venous flat-panel CT (FP-CT) was used as an adjunct to microcatheter manometry to improve decision making and precise stent placement during CVSS.

Methods: Ten consecutive patients with IIH underwent angiography with microcatheter manometry and venous FP-CT, with CVSS if indicated by the results. Cross-sectional measurements of the narrowed sinus were obtained on FP-CT before and after stenting. After the procedure, clinical outcomes were tracked. Follow-up with quantitative MRA with sinus flow measurements was also performed, when available.

Results: There was an exponential correlation between measured pressure gradient and degree of stenosis calculated using venous FP-CT. All patients with both a high degree of stenosis measured by FP-CT and a high pressure gradient across the stenosis showed a clinical benefit from stenting.

Conclusions: True measurement of the cross-sectional area of the dural sinus, made by venous phase FP-CT, has a high degree of correlation with elevated venous pressure gradient across the point of stenosis. Even in a limited series of cases, we found an exponential decrease in flow with increasing severity of stenosis. Furthermore, patients with both an elevated venous pressure gradient and critical stenosis of the sinus on FP-CT showed symptomatic improvement after stenting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11569741PMC
http://dx.doi.org/10.1177/15910199241267318DOI Listing

Publication Analysis

Top Keywords

pressure gradient
16
venous sinus
12
microcatheter manometry
12
venous
9
cerebral venous
8
stenosis
8
sinus stenosis
8
fp-ct
8
treatment idiopathic
8
idiopathic intracranial
8

Similar Publications

: Pulmonary embolism (PE) is a potentially serious condition characterized by the blockage of blood vessels in the lungs, often presenting significant diagnostic challenges due to its non-specific symptoms. This study aimed to evaluate the utility of the alveolar-arterial (A-a) oxygen gradient as a diagnostic tool for PE, hypothesizing that it could enhance early detection when combined with other clinical markers. : We retrospectively analyzed 168 patients at the University Hospital Center Split.

View Article and Find Full Text PDF

Subvalvular aortic stenosis typically manifests at a young age and rarely presents in adulthood. It may cause left ventricular outflow tract stenosis, which requires surgical treatment in severe cases. The coexistence of discrete subvalvular aortic stenosis and quadricuspid aortic valve is a highly unusual finding.

View Article and Find Full Text PDF

Arch Bare Metal Stent Grafting in Type I Aortic Dissections After Hemiarch Repair.

Ann Thorac Surg Short Rep

December 2024

Division of Cardiac Surgery, Inova Heart and Vascular Institute, Inova Health Systems, Falls Church, Virginia.

Background: DeBakey type I aortic dissections (AD) are most frequently treated with hemiarch repair. A subset of patients demonstrates persistent distal end-organ ischemia secondary to persistent true lumen (TL) compression. We describe the use of bare metal stent grafting across the residual arch dissection with the Zenith Dissection Endovascular Stent (ZDES, Cook Medical) in 7 patients with type I AD that was repaired in a hemiarch configuration with a compromised distal TL and organ malperfusion.

View Article and Find Full Text PDF

Background: The expanded polytetrafluoroethylene (ePTFE) valved conduit (VC) has been reported for pulmonary valve replacement (PVR). The purpose of this study was to review long-term outcomes of our trileaflet ePTFE VC.

Methods: This multicenter study was performed with institutional review board approval from each institution.

View Article and Find Full Text PDF

In the valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) era, implanting a larger-sized valve during the initial aortic valve replacement is important. For smaller aortic annuli, combining aortic annular and left ventricular outflow tract (LVOT) enlargement is essential. The Y-incision procedure helps achieve implantation of a 2-size larger valve.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!