Background: Optimizing patient safety in the epilepsy monitoring unit (EMU) has become a topic of increasing interest. We performed an audit of our center's new single-floor EMU, assessing intervention rate (IR), intervention time (IT), and adverse events (AEs).

Methods: A prospective study was conducted on all clinical seizures of patients admitted over a one-year period at our Canadian academic tertiary care center's new single-floor EMU. This single-floor EMU was supervised by EEG technologists during daytime (similar to the old set-up) and beneficiary attendants during nighttime/weekends (versus live video feed to the central nursing station on the neurology ward previously). Among 153 admissions, 79 were analyzed, and a total of 537 seizures were reviewed to assess IR, IT, and AEs. Univariate comparisons were performed with our double-floor EMU, which we reported in a previous publication.

Results: In our new single-floor EMU, the IR was 61.1 % and overall median IT was 29.0s (19.0s-45.9s). The AE rate was 4.8 %. Compared to previously reported numbers for our old double-floor EMU (IR = 27.8 %; IT = 21.0s; AE = 1.2 %), the IR was significantly higher ((p < 0.001) but unexpectedly, the median IT was higher (p < 0.001) as well as the AE rate (p < 0.001).

Conclusion: This prospective evaluation revealed a small but non-negligible rate of complications in our EMU, higher than our prior retrospective audit. Heightened levels of supervision in our new single-floor EMU led to higher IR. This may have led to artificially longer ITs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11381585PMC
http://dx.doi.org/10.1016/j.heliyon.2024.e35973DOI Listing

Publication Analysis

Top Keywords

single-floor emu
16
intervention time
8
time adverse
8
adverse events
8
epilepsy monitoring
8
monitoring unit
8
center's single-floor
8
double-floor emu
8
emu
7
events canadian
4

Similar Publications

Background: Optimizing patient safety in the epilepsy monitoring unit (EMU) has become a topic of increasing interest. We performed an audit of our center's new single-floor EMU, assessing intervention rate (IR), intervention time (IT), and adverse events (AEs).

Methods: A prospective study was conducted on all clinical seizures of patients admitted over a one-year period at our Canadian academic tertiary care center's new single-floor EMU.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!