In this study, the structural characteristics, functional properties, and in vitro gastrointestinal digestibility of glutenin from Tiger nut seed meal (TNSMG) treated by microwave (140-700 W, 20-60 s) and water-bath heating (40-100 °C, 10-30 min) were investigated. Analysis of the surface hydrophobicity, intrinsic fluorescence spectroscopy and Fourier transform infrared spectroscopy indicated that both microwave and water-bath heating treatments caused structure changes of TNSMG. The results showed an increase in the exposure of sulfhydryl groups and the content of β-sheet, coupled with a decrease in the content of α-helix and β-turn. These structural changes contributed to the improved solubility, foamability, emulsification properties, and digestibility of TNSMG under proper thermal treatment conditions. TNSMG exhibited the best solubility (68.48%) and foamability (85.56%) after water-bath heating treatment for 20 min at 80 °C. Furthermore, TNSMG showed the best emulsification property (9.61 m/g) and digestibility (78.58%) when treated by microwave treatment at 560 W for 40 s.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11381614 | PMC |
http://dx.doi.org/10.1016/j.fochx.2024.101741 | DOI Listing |
Int J Low Extrem Wounds
January 2025
Laser Physics Department, College of Science for Women, University of Babylon, Hillah, Iraq.
The utilization of zinc oxide nanoparticles is thought to augment wound healing because of their antibacterial characteristics and capacity to stimulate cellular regeneration, especially in instances of minor burn injuries. On the other hand, it has been shown that tissue regeneration is aided by low-power laser therapy via photobiomodulation. Zinc oxide nanoparticles and low-power laser therapy are the two therapeutic modalities that will be compared in this study in order to assess how well they promote healing after burn injury and provide important new information on improved wound care techniques.
View Article and Find Full Text PDFObjective: To determine whether a transesophageal echocardiography (TEE) probe can accurately measure temperature and be used to monitor temperature changes over time without overheating in an experimental model of hypothermia and rewarming.
Methods: A 6L water bath was heated with a sous vide immersion circulator to 24C, 28C, 32C and 36C to simulate severe hypothermia, moderate hypothermia, mild hypothermia, and normothermia. A TEE probe, esophageal temperature probe, and bladder temperature probe were used to measure temperature.
The study of heat tolerance in Drosophila melanogaster has been of particular interest to researchers for decades, with a common approach to assessing heat tolerance being to monitor the time to knockdown (TKD) after exposure to an elevated temperature. Classically, flies are housed in individual vials and placed inside a heated water bath. TKD is then monitored manually by researchers.
View Article and Find Full Text PDFInt J Biol Macromol
December 2024
College of Mechanical and Electronic Engineering, Northwest A&F University, Yangling, Shaanxi 712100, China; Department of Biological Systems Engineering, Washington State University, 213 L.J. Smith Hall, Pullman, WA 99164-6120, USA; Institute of Agro-products Storage and Processing, Xinjiang Academy of Agricultural Science, Urumqi, 830091, China. Electronic address:
J Food Prot
December 2024
University of Georgia, Department of Food Science & Technology, 100 Cedar St., Athens, GA 30602, USA.
USDA FSIS recommends meat dwell ≤6 h during cooking from 10 to 54.4 °C to limit the growth of Staphylococcus aureus and prevent its production of heat-stable enterotoxins. This study evaluated the growth of S.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!