Development of the humeral head offset index for control of humeral torsion.

BMC Musculoskelet Disord

Department of Orthopaedic Surgery, Brigham and Women's Hospital, 75 Francis St, Boston, MA, 02115, USA.

Published: September 2024

Background: Control of humeral torsion can present a challenge, especially intraoperatively during closed reduction and fixation of humeral shaft fractures or 2-part surgical neck fractures of the proximal humerus. The objective of this study is to develop and validate an indirect method for the assessment of humeral torsion using an index that is linearly correlated with rotational arm position and can be derived from only a single plain radiographic image of the proximal humerus.

Methods: The Humeral Head Offset Index (HHOI) is calculated as the ratio of the medial and lateral offset of the humeral head measured from the outer cortices of the shaft on a plain radiographic or fluoroscopic image. The relationship of HHOI with humeral torsion was first verified on a sawbone model with radiopaque characteristics under fluoroscopic control. Different degrees of retroversion were simulated through manual rotation of the humerus with a digital protractor in 5° increments until 40° internally rotated and then in 5° increments until 40° externally rotated from the neutral position. The same procedure was subsequently performed digitally on Digitally Reconstructed Radiographs (DRRs) from computed tomography (CT) dataset of the sawbone. Next, the HHOI index was applied to eight randomly selected patients with total humerus CT using the same method. Spearman's rho was calculated for the bivariate analysis of correlation between the simulated degree of retroversion and the HHOI. Strength of correlation was classified according to Koo and Li. Interrater and intrarater reliability of three blinded observers with repetition of measurement after three months were analyzed by assessing the intraclass correlation coefficient (ICC).

Results: Both in the sawbone model and in DRRs, we demonstrated a high to very high significant linear correlation between simulated retroversion and the HHOI. ICC values demonstrated excellent interrater reliability and excellent intrarater reliability for measurement of the HHOI.

Conclusions: The HHOI is a new, simple, reliable index that has a linear relationship to the rotation of the humerus and can therefore allow an indirect control of humeral torsion in comparison to the contralateral side.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11382425PMC
http://dx.doi.org/10.1186/s12891-024-07812-4DOI Listing

Publication Analysis

Top Keywords

humeral torsion
20
humeral head
12
control humeral
12
head offset
8
humeral
8
plain radiographic
8
sawbone model
8
rotation humerus
8
5° increments
8
increments 40°
8

Similar Publications

Objective: To explore changes of humerus torque screw tip distance on stability of proximal humeral internal locking system (PHILOS) by finite element analysis, in order to provide reference for selection of intraoperative plant size.

Methods: The proximal humerus 3D model was constructed based on Synbone artificial bone model in 3D engineering drawing software, and the corresponding 3D model was constructed based on PHILOS bone plate contour. The model was modified to simulate comminuted proximal humerus fracture, and the operation model was simulated after fracture, and the fixed operation model was assembled, the apex distance of humerus moment screw was set as 4, 8, 12 and 16 mm respectively.

View Article and Find Full Text PDF

Background: Pediatric supracondylar humeral fractures present considerable surgical challenges due to the difficulty of achieving proper fracture alignment and stable fixation while avoiding injury to the ulnar nerve. This study assesses the biomechanical performance of a novel Kirschner wire (K-wire) fixation device (KFD), designed to enhance stability and reduce complications linked to traditional K-wire configurations.

Methods: Using finite element analysis (FEA), we evaluated four fixation strategies for treatment of pediatric supracondylar humeral simple transverse fractures: crossed pin fixation, crossed pin fixation with KFD, two lateral pin fixation, and two lateral pin fixation with KFD, under various mechanical loads.

View Article and Find Full Text PDF

The increasing prevalence of proximal humerus fractures in the elderly population, particularly osteoporotic fractures, necessitates a biomechanical evaluation of Kirschner wire (K-wire) configurations used in percutaneous fixation. This study investigates the stability of different K-wire configurations and examines the effect of wire size and type (smooth vs. threaded).

View Article and Find Full Text PDF

Biomechanical evaluation of spiral fracture in human metacarpal using chicken humerus model.

J Hand Microsurg

December 2024

Biomechanics Laboratory, Singapore General Hospital, 20 College Road, Academia, Level 1, 169856, Singapore.

Introduction: Animal bones have been used as a model to mimic human bones for investigation of fracture patterns and fixation techniques. This study aims to investigate the effects of torsional forces of varying speeds on the spiral fracture in human metacarpal using a chicken humerus model.

Materials And Methods: Thirty fresh-frozen chicken humerus bones were dissected and equally divided into three groups.

View Article and Find Full Text PDF

Objectives: Helical plating is an established method for treating proximal humeral shaft fractures, mitigating the risk of iatrogenic radial nerve damage. However, biomechanical test data on helical plates under physiological load condition is limited. Hence, the aim of this study was to compare the biomechanical performance of helical and straight PHILOS Long plates in AO12C2 fractures using static and cyclic implant system testing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!