Background: Glaucoma is a chronic disease of the optic nerve and a leading cause of severe visual loss in the UK. Once patients have been diagnosed, they need regular monitoring at hospital eye services. Recent advances in technology mean patients with glaucoma can now monitor their disease at home. This could be more convenient for patients and potentially reduce costs and increase capacity for the NHS. However, it is uncertain whether self-monitoring would be acceptable or possible for patients with glaucoma.
Objectives: The objectives were to: identify which patients are most appropriate for home monitoring; understand views of key stakeholders (patients, clinicians, researchers) on whether home glaucoma monitoring is feasible and acceptable; develop a conceptual framework for the economic evaluation of home glaucoma monitoring; and explore the need for and provide evidence on the design of a future study to evaluate the clinical and cost-effectiveness of digital technologies for home monitoring of glaucoma.
Design: In-home Tracking of glaucoma: Reliability, Acceptability, and Cost (I-TRAC) was a multiphase mixed-methods feasibility study with key components informed by theoretical and conceptual frameworks.
Setting: Expert glaucoma specialists in the UK recruited through professional glaucoma societies; study site staff and patient participants recruited through three UK hospital eye services (England, Scotland, Northern Ireland); and UK research teams recruited though existing networks.
Intervention: Home tonometer that measures intraocular pressure and a tablet computer with a visual function application. Patients were asked to use the technology weekly for 12 weeks.
Results: Forty-two patients were recruited. Retention and completion of follow-up procedures was successful, with 95% ( = 40) completing the 3-month follow-up clinic visits. Adherence to the interventions was generally high [adherence to both devices (i.e. ≥ 80% adherence) was 55%]. Overall, patients and healthcare professionals were cautiously optimistic about the acceptability of digital technologies for home monitoring of patients with glaucoma. While most clinicians were supportive of the potential advantages glaucoma home monitoring could offer, concerns about the technologies (e.g. reliability and potential to miss disease progression) and how they would fit into routine care need to be addressed. Additionally, clarity is required on defining the ideal population for this intervention. Plans for how to evaluate value for money in a future study were also identified. However, the study also highlighted several unknowns relating to core components of a future evaluative study that require addressing before progression to a definitive effectiveness trial.
Limitations: The main limitation relates to our sample and its generalisability, for example, the over-representation of educated persons of white ethnicity who were generally experienced with technology and research motivated.
Conclusions: The In-home Tracking of glaucoma: Reliability, Acceptability, and Cost study has demonstrated 'cautious optimism' when considering patients' and healthcare professionals' views on the acceptability of digital technologies for home monitoring of patients with glaucoma. However, the study also highlighted several unknowns relating to the research question and design of a future evaluative study that require addressing before progression to a randomised controlled trial.
Future Work: Further research is required to determine the appropriate population (i.e. low vs. high risk of progression) and further refine the intervention components and delivery for planning of future evaluation studies.
Study Registration: This study is registered as Research Registry #6213.
Funding: This award was funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme (NIHR award ref: NIHR129248) and is published in full in ; Vol. 28, No. 44. See the NIHR Funding and Awards website for further award information.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11404360 | PMC |
http://dx.doi.org/10.3310/GTWD6802 | DOI Listing |
Pharmaceutics
December 2024
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81, Irwon-ro, Gangnam-gu, Seoul 06351, Republic of Korea.
This review aims to examine existing research on the development of ocular drug delivery devices utilizing hyaluronic acid (HA). Renowned for its exceptional biocompatibility, viscoelastic properties, and ability to enhance drug bioavailability, HA is a naturally occurring biopolymer. The review discussed specific mechanisms by which HA enhances drug delivery, including prolonging drug residence time on ocular surfaces, facilitating controlled drug release, and improving drug penetration through ocular tissues.
View Article and Find Full Text PDFInt J Mol Sci
December 2024
Department of Ophthalmology, University Medical Centre Ljubljana, Grablovičeva 46, 1000 Ljubljana, Slovenia.
In open-angle glaucoma, the increase in intraocular pressure (IOP) is caused by an increased resistance to aqueous humour outflow in the trabecular meshwork. Since genetic variability of matrix metalloproteinase (MMP) genes may influence extracellular matrix remodelling, we investigated their association with glaucoma risk and/or response to treatment. The retrospective part of the study included patients with primary open-angle glaucoma and ocular hypertension (OHT); in the prospective part of the study, newly diagnosed patients with POAG or OHT were randomised to receive either latanoprost or selective laser trabeculoplasty (SLT) as the initial treatment.
View Article and Find Full Text PDFMedicina (Kaunas)
November 2024
Fidia Ophthalmics, 95124 Catania, Italy.
This review highlights the therapeutic potential of epigallocatechin gallate (EGCG) and forskolin in managing retinal diseases, with a focus on glaucoma, age-related macular degeneration (AMD), and diabetic retinopathy. EGCG, a potent polyphenol from green tea, exhibits significant antioxidant, anti-inflammatory, and neuroprotective effects, making it a promising candidate for reducing oxidative stress and inflammation in ocular tissues. Forskolin, a diterpene from Coleus forskohlii, increases cyclic AMP (cAMP) levels, which helps lower intraocular pressure (IOP) and provides neuroprotection.
View Article and Find Full Text PDFJ Clin Med
December 2024
Western Eye Hospital, 153-173 Marylebone Road, London NW1 5QH, UK.
: This paper will compare the outcomes-safety and efficacy-of three minimally invasive glaucoma surgeries (MIGSs),the Hydrus Microstent, iStent, and Gonioscopy-Assisted Transluminal Trabeculotomy (GATT), for intraocular pressure (IOP) reduction in patients with primary open-angle glaucoma (POAG). : A literature search of Ovid Medline and Embase identified studies evaluating the Hydrus, iStent, and GATT. Data on IOP reduction, medication use, and complications were analyzed.
View Article and Find Full Text PDFJ Clin Med
December 2024
Swiss Visio Glaucoma Research Center, Montchoisi Clinic, 1006 Lausanne, Switzerland.
This study compares the long-term intraocular pressure (IOP)-lowering efficacy of standalone MINIject (iSTAR Medical, Belgium) suprachoroidal implantation and two iStent (Glaukos, CA, USA) trabecular bypass implantation using a systematic review and meta-analysis. Systematic review of standalone implantation of MINIject or iStent inject with at least 24 months of follow up. The mean and standard deviation of IOP and the number of IOP-lowering medications at baseline and at 24 months were extracted.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!