Drug-coated balloons have emerged as a promising therapeutic option in the treatment of cardiovascular disease. This review article provides an overview of the concept of drug-coated balloons and their clinical applications in both de novo and treated coronary artery disease. A summary of key clinical trials and registry studies evaluating drug-coated balloons is presented for reference. Overall, this article aims to provide clinicians and researchers with a comprehensive understanding of the current state of drug-coated balloon technology and its implications in clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.tcm.2024.08.006DOI Listing

Publication Analysis

Top Keywords

drug-coated balloons
16
clinical applications
8
coronary drug-coated
4
balloons
4
balloons comprehensive
4
comprehensive review
4
clinical
4
review clinical
4
applications controversies
4
drug-coated
4

Similar Publications

Background: Drug-coated balloons present a potentially advantageous therapeutic approach for managing coronary in-stent restenosis (ISR). However, the comparative benefits of paclitaxel-coated balloons (PCBs) over uncoated balloons (UCBs) remain unclear.

Aims: We conducted a systematic review and meta-analysis to evaluate and compare the clinical outcomes of patients treated with PCBs and UCBs.

View Article and Find Full Text PDF

Recurrent drug eluting stent, in-stent restenosis (DES-ISR): Epidemiology, pathophysiology & treatment.

Prog Cardiovasc Dis

January 2025

Division of Cardiovascular Medicine, Department of Medicine, University of Virginia Health System, 1215 Lee Street, Charlottesville, VA 22909, United States of America. Electronic address:

Coronary artery in-stent restenosis (ISR) is driven by neointimal hyperplasia and neoatherosclerosis in previously placed stents. Drug eluting stents (DES) have been adopted as first line therapy for the initial episode of ISR. However, recurrent ISR has limited durable salvage options.

View Article and Find Full Text PDF

Background: Because of the limitations in new-generation drug-eluting stents (DES), treatments advocating for non-stents with a drug-coated balloon (DCB) is now of great interest. Here, we conducted a meta-analysis to testify whether a DCB was more effective and safer than a DES in treating de novo coronary artery disease (CAD).

Methods: We searched PubMed, Embase, Cochrane Library, and Web of Science to obtain high-quality trials comparing DCB with DES for the treatment of de novo CAD.

View Article and Find Full Text PDF

Recent Advances in the Treatment of Coronary In-Stent Restenosis.

Rev Cardiovasc Med

December 2024

Department of Cardiology, Bern University Hospital, Inselspital, CH-3010 Bern, Switzerland.

In-stent restenosis (ISR) remains the predominant cause of stent failure and the most common indication for repeat revascularization. Despite technological advances in stent design, ISR continues to pose significant challenges, contributing to increased morbidity and mortality among patients undergoing percutaneous coronary interventions. In the last decade, intravascular imaging has emerged as an important method for identifying the mechanisms behind ISR and guiding its treatment.

View Article and Find Full Text PDF

An 82-year-old woman with a history of myocardial infarction presented with worsening effort angina. Coronary angiography (CAG) revealed 75% stenosis in the proximal left anterior descending artery (LAD), with intravascular ultrasound (IVUS) identifying a severe calcified nodule near a previously implanted drug-eluting stent. The lesion was treated with intravascular lithotripsy (IVL) and a drug-coated balloon (DCB), avoiding left main crossover stenting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?