Rationale And Objectives: The emergence of low-dose protocols for CT imaging has mitigated pediatric radiation exposure, yet ionizing radiation remains a concern for children with complex craniofacial conditions requiring repeated radiologic monitoring. In this work, the clinical feasibility of an ultrashort echo time (UTE) MRI sequence was investigated in pediatric patients.

Materials And Methods: Twelve pediatric patients (6 female, age range 8 to 18 years) with various imaging conditions were scanned at 3T using a dual-radiofrequency, dual-echo UTE MRI sequence. Bright-bone images were generated using a weighted least-squares conjugate gradient method to enhance bone specificity. The overlap of the binary skull masks was quantified using the Dice similarity coefficient (DSC) and the 95th percentile Hausdorff distance (HD95) to evaluate the similarity between MRI and CT. To assess the anatomic accuracy of 3D skull reconstructions, six craniometric distances were recorded and the agreement between MRI- and CT-derived measurements was evaluated using Lin's concordance correlation coefficient (ρ).

Results: The bright-bone images from UTE MRI demonstrated high bone-contrast, suppression of soft tissue, and separation from air at the sinuses. The DSC and HD95 between MRI and CT had medians of 0.81 ± 0.10 and 1.87 ± 0.32 mm, respectively. There was good agreement between MRI and CT for all craniometric distances (ρ ranging from 0.90 to 0.99) with a mean absolute difference in measurements of < 2 mm.

Conclusion: The clinical feasibility of the UTE MRI sequence for craniofacial imaging was demonstrated in a cohort of pediatric patients, showing good agreement with CT in resolving thin bone structures and craniometry.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11525957PMC
http://dx.doi.org/10.1016/j.acra.2024.08.053DOI Listing

Publication Analysis

Top Keywords

ute mri
12
pediatric patients
8
mri sequence
8
bright-bone images
8
craniometric distances
8
mri
7
craniofacial imaging
4
pediatric
4
imaging pediatric
4
patients ultrashort
4

Similar Publications

Utilizing a multi-task deep learning framework, this study generated synthetic CT (sCT) images from a limited dataset of Ultrashort echo time (UTE) MRI for transcranial focused ultrasound (tFUS) planning. A 3D Transformer U-Net was employed to produce sCT images that closely replicated actual CT scans, demonstrated by an average Dice coefficient of 0.868 for morphological accuracy.

View Article and Find Full Text PDF

Introduction: Restricted fetal and neonatal growth is a known risk factor for bronchopulmonary dysplasia (BPD) in premature infants. However, the impact of nutrition and infant growth specifically on lung growth in BPD in unknown. Moreover, whether all lung growth in BPD is beneficial is unclear.

View Article and Find Full Text PDF

Importance of integrin transmembrane helical interactions for antagonistic versus agonistic ligand behavior: Consequences for medical applications.

Bioorg Chem

January 2025

Institute for Advanced Study, Department of Chemistry, School of Natural Sciences and Bavarian NMR Center (BNMRZ), Technical University Munich, Ernst-Otto-Fischer-Str. 2, 85748 Garching, Germany. Electronic address:

Integrins are well-characterized receptors involved in cell adhesion and signaling. With six approved drugs, they are recognized as valuable therapeutic targets. Here, we explore potential activation mechanisms that may clarify the agonist versus antagonist behavior of integrin ligands.

View Article and Find Full Text PDF

Purpose: Pulmonary MRI faces challenges due to low proton density, rapid transverse magnetization decay, and cardiac and respiratory motion. The fermat-looped orthogonally encoded trajectories (FLORET) sequence addresses these issues with high sampling efficiency, strong signal, and motion robustness, but has not yet been applied to phase-resolved functional lung (PREFUL) MRI-a contrast-free method for assessing pulmonary ventilation during free breathing. This study aims to develop a reconstruction pipeline for FLORET UTE, enhancing spatial resolution for three-dimensional (3D) PREFUL ventilation analysis.

View Article and Find Full Text PDF

Objective: This study aims to evaluate the efficacy of two free-breathing magnetic resonance imaging (MRI) sequences-spiral ultrashort echo time (spiral UTE) and radial volumetric interpolated breath-hold examination (radial VIBE).

Methods: Patients were prospectively enrolled between February 2021 and September 2022. All participants underwent both 3T MRI scanning, utilizing the radial VIBE sequence and spiral UTE sequence, as well as standard chest CT imaging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!