A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of interface dead space on the time taken to achieve changes in set FiO during T-piece ventilation: is face mask the optimal interface for neonatal stabilisation? | LitMetric

Background: T-piece is recommended for respiratory support during neonatal stabilisation. Bench studies have shown a delay >30 s in achieving changes in fraction of inspired oxygen (FiO) at the airway when using the T-piece. Using a face mask adds dead space (DS) to the patient airway. We hypothesised that adding face mask to T-piece systems adversely affects the time required for a change in FiO to reach the patient.

Methods: Neopuff (Fisher and Paykel, Auckland, New Zealand) and rPAP (Inspiration Healthcare, Croydon, UK) were used to ventilate a test lung. DS equivalent to neonatal face masks was added between the T-piece and test lung. Additionally, rPAP was tested with nasal prongs. Time course for change in FiO to be achieved at the airway was measured for increase (0.3-0.6) and decrease (1.0-0.5) in FiO. Primary outcome was time to reach FiO+/-0.05 of the set target. One-way analysis of variance was used to compare mean time to reach the primary outcome between different DS volumes.

Results: In all experiments, the mean time to reach the primary outcome was significantly shorter for rPAP with prongs compared with Neopuff and rPAP with face mask DS (p<0.001). The largest observed difference occurred when testing a decrease in FiO with 10 mL tidal volume (TV) without leakage (18.3 s for rPAP with prongs vs 153.4 s for Neopuff with face mask DS). The shortest observed time was 13.3 s when increasing FiO with 10 mL TV with prongs with leakage and the longest time was 172.7 s when decreasing FiO with 4 mL TV and added face mask DS without leak.

Conclusion: There was a delay in achieving changes in oxygen delivery at the airway during simulated ventilation attributable to the mask volume. This delay was greatly reduced when using nasal prongs as an interface. This should be examined in clinical trials.

Download full-text PDF

Source
http://dx.doi.org/10.1136/archdischild-2024-327236DOI Listing

Publication Analysis

Top Keywords

face mask
16
primary outcome
12
time reach
12
dead space
8
change fio
8
test lung
8
reach primary
8
time
6
fio
5
t-piece
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!