Twelve patients (4.3-25.3 kg) undergoing minor surgical procedures were investigated during halothane anaesthesia with spontaneous breathing through a modified T-piece (Mapleson F) with an apparatus deadspace that could be changed from 2 ml (VDsmall) to 16 ml (VDlarge). Immediately following the switch from VDsmall to Vlarge ETCO2 (mean +/- 1 SD) increased from 6.89 +/- 1.09% to 7.61 +/- 1.14% (ns) then gradually decreased during a 10-min period. The initial plateau of FlCO2 (mean +/- 1 SD) with VDlarge was 0.74 +/- 0.34%, but gradually decreased to 0.63 +/- 0.25% after 10 min. This was achieved by an increase in VE (P less than 0.05 by 2 min). After 10 min VE had increased by more than 40% (P less than 0.01) as a result of an increase in VT (mean +/- 1 SD) of 14.6 +/- 6.5 ml. After 10 min of VDlarge ventilation, VA and VCO2 were maintained at VDsmall values. The adequate ventilatory response to the large deadspace was seen in all patients, but the ventilatory efficiency, as judged by VD/VT and VENCO2 ratios, was reduced significantly in the children weighing less than 10 kg.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/bja/57.6.562 | DOI Listing |
J Caring Sci
November 2021
Department Intensive Care Nursing, Faculty of Nursing and Midwifery, Mashhad University of Medical Sciences, Mashhad, Iran.
After abdominal surgery, the patients who are separated from mechanical ventilation and provided with oxygen therapy via a T-piece are at risk for respiratory complications. Therefore, they need additional respiratory support. This study aimed to evaluate the effects of manual hyperinflation (MHI) on pulmonary function after weaning.
View Article and Find Full Text PDFPaediatr Anaesth
November 2014
Department of Anaesthetics, Queen Elizabeth Central Hospital, Blantyre, Malawi.
Background: Inhalational induction in children is easiest to perform with the Ayres t-piece & bag (Mapleson F). Drawover anesthesia systems may be used but have not been studied. The aim of this study was to examine the quality of induction of anesthesia in children comparing a continuous flow system using the Farman entrainer and the pediatric t-piece, to a pediatric drawover system.
View Article and Find Full Text PDFUgeskr Laeger
October 2002
Kolding Sygehus, anaestesiologisk afdeling.
The Bain circuit is a modification of the Mapleson D ventilation system used in general anaesthesia in children and adults. It has several advantages over other systems as it is light in weight, convenient, and has no valves. But it contains the risk of undetected leak or occlusion, because of its construction with a small inner tube, which provides the patient with fresh gas, inside a larger corrugated tube.
View Article and Find Full Text PDFBr J Anaesth
December 1987
Department of Anaesthesia, Hospital for Sick Children, London.
The influence of fresh gas flow (FGF) setting on rebreathing was investigated in 15 infants and children (weight 3.5-21.8 kg) during balanced anaesthesia with mechanically controlled ventilation using a T-piece (Mapleson E) system and a Nuffield ventilator 200.