Statement Of Problem: The demand for immediate implant placement (IIP) in the esthetic zone is rapidly increasing. Despite the treatment's benefits, the sagittal root position often dictates implant angulation, commonly necessitating the use of cement-retained restorations. This study investigates the impact of angulated screw channel on IIP in the esthetic zone.

Purpose: The purpose of this cone-beam computed tomography (CBCT) study was to determine the probability of IIP in the esthetic zone, using four different implant angulations.

Materials And Methods: A retrospective review of CBCT images was conducted and accessed on 9 June 2021. The midsagittal images of maxillary anterior teeth were input into an implant planning software (Implant Studio®). Bone Level X Straumann® implant (BLX 3.5, 3.75, 4.0, 4.5, 5.0 mm) and Bone Level Tapered implant (BLT 2.9, 3.3 mm) were selected for 3D implant planning of IIP in the esthetic zone. The frequency distribution and probability of IIP were recorded and compared among all maxillary anterior teeth.

Results: CBCT images from 720 teeth (120 patient) were evaluated, revealing an overall probability of IIP in the esthetic zone is 76.11% (548/720). Different implant restoration type was evaluated in this study, with the following results; straight screw-retained prosthesis at 3.47% (19/548), cement-retained prosthesis at 14.59% (80/548) and angle screw-retained prosthesis at 85.40% (468/548).

Conclusion: IIP with traditional straight screw-retained prosthesis demonstrated the lowest probability. Nevertheless, the use of angulated screw channels enhances the probability of achieving straight screw-retained prostheses.

Clinical Implications: The angulated screw channel is essential for increasing the probability of screw-retained prosthesis in IIP in the esthetic zone. However, limitation in screw angle correction still necessitate the use of cement-retained prostheses for numbers of patients undergoing IIP.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11376541PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0308158PLOS

Publication Analysis

Top Keywords

esthetic zone
24
iip esthetic
24
angulated screw
16
screw-retained prosthesis
16
screw channel
12
probability iip
12
straight screw-retained
12
implant
10
iip
9
implant placement
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!