During thyroidectomy, both needle electrodes (NE) and endotracheal tube electrodes (ETE) can be used. Incomplete contact of the endotracheal tube electrode with the vocal cords, endotracheal tube electrode may hinder an optimal outcome and even result in an inability to obtain an electromyography wave while neuromonitoring the external branch of the superior laryngeal nerve (EBSLN). There is no study that compares NE and ETE for EBSLN monitoring. Therefore, this study compares NE and ETE recordings during EBSLN monitoring. Twenty-six consecutive patients undergoing total thyroidectomy were included in this study. Intraoperative neuromonitoring was performed simultaneously with both NEs and ETEs. Pre-resection (V1, R1, and S1) and post-resection (V2, R2, and S2) amplitudes and latencies were recorded for both types of electrodes. The Mann-Whitney U test was used for statistical analysis. Twenty-one women and five men were included, and 52 nerves at risk were evaluated. The mean amplitudes for right S1 (314 vs. 168 µV, p = 0.009) and right S2 (428 vs. 161 µV, p: 0.001) and for left S1 (346 vs. 229 µV, p: 0.017) and left S2 (413 vs. 229 µV, p: 0.009) were statistically higher for the NE group. All amplitudes obtained using NEs, except on the left for V1, R1, V2, and R2, were statistically higher than those obtained using ETEs. There was no loss of signal or vocal cord palsy in the patients. There were no needle-related complications. EBSLN monitoring using NE is a safe alternative to ETE. With NE, higher amplitudes were obtained. Level of evidence: Level 3.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s13304-024-01982-5DOI Listing

Publication Analysis

Top Keywords

endotracheal tube
16
ebsln monitoring
16
tube electrodes
8
tube electrode
8
study compares
8
compares ete
8
statistically higher
8
ebsln
5
thyroid cartilage
4
cartilage needle
4

Similar Publications

Fungal infections related to biofilm formation on medical devices, such as endotracheal tubes (ETTs), pose significant health risks, especially during intubation procedures where fungi like Candida spp. can migrate into the lower respiratory tract. This study explores the use of Photodynamic Therapy (PDT) to prevent fungal cell migration from ETT surfaces to lungs, focusing on the role of curcumin as a photosensitizer.

View Article and Find Full Text PDF

Application of a novel gastro-laryngeal mask in upper gastrointestinal endoscopy surgery: A pilot randomized clinical trial.

Anaesth Crit Care Pain Med

December 2024

Department of Anesthesiology, Pain and Perioperative Medicine, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China. Electronic address:

Background: The Gastro-Laryngeal Mask (Jcerity Endoscoper Airway) is a new airway management technique utilized in patients undergoing upper gastrointestinal endoscopy surgery under general anesthesia, but evidence of its effectiveness and safety is scarce.

Objective: To assess the success rate of insertion, cardiovascular response, airway pressure, time taken for placement, nausea or vomiting, pharyngodynia, and other complications of using the new type of back-open gastroscopy laryngeal mask.

Methods: We screened 1401 patients; 105 were ineligible, and 40 declined to participate.

View Article and Find Full Text PDF

Background: The difficult airway is frequently encountered across many scenarios. The extreme form is a "cannot intubate and cannot oxygenate" scenario, which lacks a reliable rescue technique. Previous case reports or studies with small sample sizes indicate the feasibility and efficiency of an endotracheal tube in the pharynx (TTIP) to ventilate patients.

View Article and Find Full Text PDF

Foreign body (FB) aspiration in children is a common emergency. Traditionally, rigid bronchoscopy has been considered to be the mainstay for removal. However, in certain cases, flexible bronchoscopy can prove to be a better option and avoid thoracic surgery and unnecessary morbidity.

View Article and Find Full Text PDF

Background: Elective ventilation and paralysis have been shown to decrease the anastomosis-related complications following primary repair of esophageal atresia (EA). Repeated endotracheal tube (ETT) block and replacement can increase these complications. We evaluated the results of our strategy of electively changing the ETT just before shifting the patient to the postoperative ward for elective ventilation.

View Article and Find Full Text PDF