Hydrodissection and femtosecond laser assisted surgery in posterior polar cataract.

Int Ophthalmol

Ein-Tal Eye Center, 15 Habarzel St, 6971021, Tel Aviv, Israel.

Published: September 2024

Purpose: To present our clinical experience using femtosecond laser-assisted cataract surgery (FLACS) and cortical cleavage hydrodissection in eyes with posterior polar cataract.

Methods: Medical records of consecutive10 eyes of 6 patients with clinical diagnosis of posterior polar cataract (PPC), were retrospectively reviewed. All surgeries were done by using femtosecond laser-assisted cataract surgery. In all cases careful hydrodissection was done to separate the lens material from the posterior capsule.

Results: There were 3 males and 3 females, ages 39-73 years (average 52.5 years), two of them were implanted with toric lenses. In all eyes hydrodissection was successfully performed and the lens material was separated from the lens capsule. The posterior capsule remained intact during nucleus removal in all cases. In one eye the posterior capsule broke during cortical cleaning and the tear was converted to posterior capsulorhexis (PCCC). No postoperative complications were recorded during follow-up in all eyes.

Conclusions: Hydrodissection can be safely performed in combination (but not exclusively) with FLACS, in eyes with posterior polar cataract with no evidence of a preexisting posterior capsule rent. Hydrodissection is regarded by most surgeons as contraindicated in these eyes however apparently it is more gentile to the capsule than any other surgical maneuver and allows clean and efficient separation of the lens material from the thinned posterior capsule. Femtosecond laser capsulotomy and lens fragmentation is effective and may further assist surgery by pneumo-separation of the lens material. Anterior chamber maintainer may further aid to the stability of the chamber and safety of surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11377625PMC
http://dx.doi.org/10.1007/s10792-024-03286-4DOI Listing

Publication Analysis

Top Keywords

posterior polar
16
lens material
16
posterior capsule
16
polar cataract
12
posterior
10
femtosecond laser
8
femtosecond laser-assisted
8
laser-assisted cataract
8
eyes posterior
8
hydrodissection
6

Similar Publications

Purpose: This work described a new species of Ceratomyxa, based on morphological and phylogenetic analyzes of myxospores collected from the gallbladder of the fish Astyanax mexicanus.

Methods: Sixty-two specimens were captured, between December 2022 and February 2024, in the Flexal River, in the community of Tessalônica, state of Amapá. The specimens were transported alive to the Laboratory of Morphophysiology and Animal Health, at the State University of Amapá, where the studies were carried out.

View Article and Find Full Text PDF

In the early Drosophila embryo, germband elongation is driven by oriented cell intercalation through t1 transitions, where vertical (dorsal-ventral aligned) interfaces contract and then resolve into new horizontal (anterior-posterior aligned) interfaces. Here, we show that contractile events produce a continuous "rectification" of cell interfaces, in which interfaces systematically rotate toward more vertical orientations. As interfaces rotate, their behavior transitions from elongating to contractile regimes, indicating that the planar polarized identities of cell-cell interfaces are continuously re-interpreted in time depending on their orientation angle.

View Article and Find Full Text PDF

We describe and characterize a new species from the Singing honeyeater () in Western Australia, both morphologically and molecularly. Microscopic analysis of a fecal sample identified 25 ellipsoidal oocysts, measuring 21-25 × 18-20 μm (mean 23.4 × 18.

View Article and Find Full Text PDF

Purpose: Henneguya sp. is a crucial myxosporean parasite known to cause milky flesh or tapioca disease in the freshwater fish population, leading to heavy mortality. Studies to investigate its host range and to monitor their prevalence in wild and aquacultured fish are necessary.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess the predictive accuracy of a new nephrometry model (RSR) for nephron-sparing surgery in pediatric patients with Wilms tumor, comparing it to existing models.
  • Data from 58 pediatric patients were analyzed, calculating nephrometry scores such as RENAL, PADUA, and SPARE, and the RSR model showed superior predictive performance with an area under the curve (AUC) of 0.982.
  • The RSR model not only outperformed the other nephrometry scores significantly but also demonstrated good inter-rater reliability, leading to the development of a user-friendly web-based calculator for its application.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!