Heteroepitaxial interfaces are important because they determine the performance of devices such that career mobility is sensitive to the distribution of roughness, strain and composition at the interface. High-angle annular dark field imaging in scanning transmission electron microscopy has been utilized to capture them at an atomic scale. For precise identification of atomic column positions, a technique has been proposed to average multiple image frames taken at a high scanning rate by their positional alignment for increasing signal-to-noise ratio. However, the positional alignment between frames is sometimes incorrectly estimated because of the almost perfect periodic structure at the interfaces. Here, we developed an approach for precise positional alignment, where the images are first aligned by two consecutive images and then are aligned more precisely against the integrated image of the first alignment. We demonstrated our method by applying it to the heterointerface of Si0.8Ge0.2 (Si: silicon, Ge: germanium) epitaxial thin films on a Si substrate.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jmicro/dfae038DOI Listing

Publication Analysis

Top Keywords

positional alignment
16
precise positional
8
signal-to-noise ratio
8
images aligned
8
alignment
5
alignment atom-resolved
4
atom-resolved haadf
4
haadf images
4
images heteroepitaxial
4
heteroepitaxial interface
4

Similar Publications

Background: This study examines the relationship between the anterior offset of the tibial intramedullary nail (TIN) entry point and the tibial shaft axis to enhance the fit and alignment of TINs, using transparent 3D-CT in an accurate lateral view to minimize rotational artifacts.

Methods: Data were collected from 100 adult patients undergoing tibial CT scans. Measurements included the anterior offset from the tibial axis to the entry point, tibial tubercle offset, tibial plateau length, posterior slope, tibial length, isthmus diameter, and the isthmus-to-tibial length ratio.

View Article and Find Full Text PDF

Objective: The effect of different attachment positions on torque control during the labialization of maxillary lateral incisors with clear aligners was evaluated using finite element analysis.

Methods: Anatomical data acquired through cone-beam computed tomography, combined with the design of 0.625-mm-thick aligners and horizontal attachments, were integrated into the software.

View Article and Find Full Text PDF

Can robotic arm-assisted total knee arthroplasty be applied to valgus deformity.

Arch Orthop Trauma Surg

January 2025

Department of Orthopaedic Surgery, University Hospital centre (Saint Etienne), Avenue Albert Raimond, Saint-priest-en-Jarez, 42270, France.

Introduction: Total knee arthroplasty (TKA) in valgus knees is challenging. Optimal ligament balance, implant neutral or moderate valgus alignment are crucial but conventional instrumentations usually lead to outliers. Robotic arm assisted TKA (RATKA) advantages could answer this challenge.

View Article and Find Full Text PDF

Objective: To evaluate the early effectiveness of navigation-free robot-assisted total knee arthroplasty (TKA) compared to traditional TKA in the treatment of knee osteoarthritis combined with extra-articular deformities.

Methods: The clinical data of 30 patients with knee osteoarthritis combined with extra-articular deformities who met the selection criteria between June 2019 and January 2024 were retrospectively analyzed. Fifteen patients underwent CORI navigation-free robot-assisted TKA and intra-articular osteotomy (robot group) and 15 patients underwent traditional TKA and intra-articular osteotomy (traditional group).

View Article and Find Full Text PDF

Exploring online patient-doctor interactions. An epistemic and pragmatic analysis of Q&A patterns in an Italian "Ask to the doctor" medical forum.

Patient Educ Couns

January 2025

Department of Education, Cultural Heritage and Tourism, University of Macerata, Piazzale L. Bertelli, 1, Macerata 62100, Italy. Electronic address:

The main objective of this research is to investigate the epistemic and pragmatic management of patient-doctor interactions in Italian online health communities. To achieve this goal, an advanced web scraping methodology was used to extract from an Italian Q&A service (within the healthcare platforms, Il Mio Dottore) 200 pairs of questions and answers concerning two pathological conditions: anxiety and hypothyroidism. We first tagged the two sub-corpora and analyzed them both quantitatively and qualitatively to establish (i) what types of questions were used by patients, and what epistemic attitude and pragmatic function they convey; (ii) whether doctors' replies were aligned or not; (iii) whether there were differences between the two sub-corpora.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!