Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: To investigate the effects of transpalatal (TPA) wire dimension and temporary skeletal anchorage device (TSAD) position on maxillary molar intrusion.
Materials And Methods: The maxillary molar intrusion measurement system included a maxillary acrylic model, TPA, TSADs, and a three-dimensional Force/Moment (F/M) sensor. The intrusion patterns were categorized into six groups: buccal-mesial, buccal-distal, buccal-mesiodistal, palatal-mesial, palatal-distal, and palatal-mesiodistal. TPA wire dimensions were designed to be 0.7 mm, 0.9 mm, and 1.2 mm. The force and moment loads of the maxillary first molar were measured by the F/M sensor.
Results: Single buccal or palatal TSADs induced torquing movement, and single mesial or distal TSADs tended to promote tipping movement. Mesiodistal TSADs would have eliminated tipping, but accentuated torquing movement. The TPA significantly reduced the force and moment experienced by the maxillary first molar along three-dimensional axes. The thicker the TPA wire, the smaller the force and moment to which the maxillary first molar was subjected.
Conclusions: Precise placement of TSADs might have a substantial influence on tooth movement and should be determined in accordance with specific clinical requirements. Increasing the TPA wire dimension could diminish the tipping, torquing, and rotation during TSAD-assisted maxillary molar intrusion, but these tendencies could not be completely eliminated.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11210518 | PMC |
http://dx.doi.org/10.2319/102423-721.1 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!