A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of transpalatal arch wire dimension and temporary skeletal anchorage device position on maxillary molar intrusion. | LitMetric

Objectives: To investigate the effects of transpalatal (TPA) wire dimension and temporary skeletal anchorage device (TSAD) position on maxillary molar intrusion.

Materials And Methods: The maxillary molar intrusion measurement system included a maxillary acrylic model, TPA, TSADs, and a three-dimensional Force/Moment (F/M) sensor. The intrusion patterns were categorized into six groups: buccal-mesial, buccal-distal, buccal-mesiodistal, palatal-mesial, palatal-distal, and palatal-mesiodistal. TPA wire dimensions were designed to be 0.7 mm, 0.9 mm, and 1.2 mm. The force and moment loads of the maxillary first molar were measured by the F/M sensor.

Results: Single buccal or palatal TSADs induced torquing movement, and single mesial or distal TSADs tended to promote tipping movement. Mesiodistal TSADs would have eliminated tipping, but accentuated torquing movement. The TPA significantly reduced the force and moment experienced by the maxillary first molar along three-dimensional axes. The thicker the TPA wire, the smaller the force and moment to which the maxillary first molar was subjected.

Conclusions: Precise placement of TSADs might have a substantial influence on tooth movement and should be determined in accordance with specific clinical requirements. Increasing the TPA wire dimension could diminish the tipping, torquing, and rotation during TSAD-assisted maxillary molar intrusion, but these tendencies could not be completely eliminated.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11210518PMC
http://dx.doi.org/10.2319/102423-721.1DOI Listing

Publication Analysis

Top Keywords

maxillary molar
28
tpa wire
16
wire dimension
12
molar intrusion
12
force moment
12
effects transpalatal
8
dimension temporary
8
temporary skeletal
8
skeletal anchorage
8
anchorage device
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!