A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Highly sensitive biosensors for real-time monitoring of histamine at acupoint PC6 in rats based on graphene-modified acupuncture needles. | LitMetric

Acupoints are the local initial response sites of acupuncture therapeutic effects. As a biomarker, histamine is released into the acupoint region and plays its role concurrently as acupuncture needles are inserted into acupoints. Hence, real-time monitoring of histamine at acupoints is important to elucidate the effectiveness of the acupoint-activation process in acupuncture. Therefore, we developed highly sensitive acupuncture/Au particles/graphene biosensors by electrodeposition, brushing, and annealing methods based on bare acupuncture needles. We achieved a histamine detection limit of approximately 4.352 (±3.419) × 10 mol L and good sensitivity of approximately 6.296 (±3.873) μA μM, with satisfactory specificity, repeatability, and stability , rendering them more competitive and suitable for real-time monitoring without causing additional damage. Subsequently, we conducted real-time histamine monitoring at non-acupoint and acupoint PC6 in rats, respectively. Our results showed minimal changes at the non-acupoint, whereas a trend of initial increase followed by a decrease was observed at acupoint PC6. The change in histamine concentration at acupoint PC6 reflected its involvement in the acupoint-activation procedure. Moreover, its peak position at ∼18 min could provide guidance for optimizing needle retaining time for maximum therapeutic effect. This work presents the first real-time monitoring of histamine at acupoints with high sensitivity and underscores the specificity of histamine release between non-acupoint and acupoint PC6, demonstrating great potential for elucidating the acupoint-activation mechanisms in acupuncture. Additionally, this work expands the application of nanomaterials in the integration of medicine and engineering, which is an important aspect of the future development of materials science.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d4nr01998aDOI Listing

Publication Analysis

Top Keywords

acupoint pc6
20
real-time monitoring
16
monitoring histamine
12
acupuncture needles
12
highly sensitive
8
histamine
8
pc6 rats
8
histamine acupoints
8
non-acupoint acupoint
8
acupoint
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!