Assessment of the Omius™ cooling headband effectiveness during a 70-min submaximal running effort followed by a 5-km time-trial in hot/humid conditions.

J Therm Biol

Faculty of Physical Activity Sciences, Université de Sherbrooke, Sherbrooke, Québec, Canada; Research Centre on Aging, Université de Sherbrooke, Sherbrooke, Québec, Canada. Electronic address:

Published: August 2024

Exercise performed under hot/humid conditions can hinder endurance performance. The Omius™ headband (OH) is purported to reduce the perception of heat and improve performance. We examined the impact of OH on selected thermal and cardiovascular functions, subjective perceptions and running performance. Using a randomized crossover protocol, 10 trained male athletes (28 ± 4 years) completed two trials (OH and sham headband (SH), 35.0 ± 0.3 °C, 56 ± 3% relative humidity) comprising 70 min of running (60% V˙O) followed by a 5-km running time-trial (TT). Heart rate, perceived exertion and whole-body thermal comfort did not significantly differ between conditions during the submaximal running effort and TT. Rectal temperature was higher with OH (0.11 ± 0.16 °C, p = 0.052) than SH prior to the submaximal running effort, however, no significant differences were observed between conditions regarding the changes in rectal temperature from baseline during the submaximal running effort and TT. Forehead temperature was significantly lower with OH than SH during the submaximal running effort, but no significant differences were observed at the end of the TT. Scores of perceived forehead thermal comfort were only significantly lower with OH than SH during the submaximal running effort. TT performance did not significantly differ between OH (19.8 ± 1.2 min) and SH (20.2 ± 1.0 min). In conclusion, OH improves forehead thermal comfort and reduces forehead temperature but not rectal temperature, heart rate and perceived exertion during, nor 5-km TT performance following, 70 min of submaximal running in the heat.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtherbio.2024.103964DOI Listing

Publication Analysis

Top Keywords

submaximal running
28
running effort
24
thermal comfort
12
rectal temperature
12
running
10
hot/humid conditions
8
heart rate
8
rate perceived
8
perceived exertion
8
effort differences
8

Similar Publications

End-tidal CO and ventilation: Novel markers for assessing performance levels in elite long-distance runners.

Respir Physiol Neurobiol

December 2024

The University of Sydney, Faculty of Medicine and Health, Susan Wakil Health Building, Western Avenue, Camperdown, NSW 2050, Australia. Electronic address:

Well-trained individuals, compared to less well-trained individuals, exhibit a lower minute ventilation (V̇) and higher end-tidal partial pressure of CO (PCO) at a given work rate. This study investigated whether such breathing adaptations seen in well-trained individuals also applied to elite long-distance runners. Forty-one long-distance runners were categorized into high (Long-High, consisting of Tokyo-Hakone College Ekiden [relay marathon] runners and Olympic athletes, n = 23), or low performance-level group (Long-Low, n = 18) according to their race times.

View Article and Find Full Text PDF

Introduction: Type 2 diabetes, characterized by hyperglycemia, is closely linked to obesity and low-grade inflammation. Acute cocoa flavanols (CF) intake has demonstrated benefits in vasoreactivity, cognitive functions, and antioxidant enzyme activity. However, the physiological mechanisms of CF concerning glucose uptake, inflammatory mediators, and their interplay with aerobic exercise remain unclear in populations with metabolic diseases.

View Article and Find Full Text PDF

Purpose: In world-class middle- and long-distance running races, a Wavelight signal has recently been used as a pacing guide for setting records. The aim of the present study was to compare performance and psychophysiological effects between light-guided, drafting, and nonassisted pacing conditions in distance runners.

Methods: Fifteen male middle- and long-distance runners of national and regional standard ran three 5000-m time trials in a counterbalanced order with the following pacing distribution: the first 4000 m and last 1000 m were covered at submaximal and maximal intensities, respectively.

View Article and Find Full Text PDF

Anterior cruciate ligament (ACL) tears are due to jumping, rapid decelerating, or quick changes in direction, but recent research indicates that accumulated tissue fatigue from repetitive submaximal knee loading can also cause ACL disruption. Partial degenerative ACL tears due to overuse are currently thought to be asymptomatic until the ligament is at least 50% torn. In this case, a 36-year-old female runner presenting with sharp lateral joint line knee pain, which precluded running or hiking over one mile, was found to have an atraumatic 10% thickness ACL tear.

View Article and Find Full Text PDF

Transcranial direct current stimulation (tDCS), a non-invasive brain stimulation technique, has been shown to increase exercise performance in strength and cycling studies but its effects on running endurance remain unclear. The objectives of this randomized sham-controlled crossover trial were to assess tDCS efficacy on submaximal treadmill running time to exhaustion (TTE). Forty-five healthy male runners aged between 18 and 32 years (mean maximal oxygen consumption: 46.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!