Persistent left superior vena cava (PLSVC) is one of the anatomical variations, which can make device implantation more challenging and lead to incorrect lead placement, dislodgement, and procedure failure. Conduction system pacing (CSP) can be an alternative to traditional CRT implantation. Herein, we describe a brief case report of successful LBBAP-optimized CRT (LOT-CRT) via an innominate vein in a patient with PLSVC.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/pace.15068 | DOI Listing |
Cureus
December 2024
Cardiology, Quillen College of Medicine, East Tennessee State University, Johnson City, USA.
Cardiac implantable electronic devices (CIEDs), including pacemakers, implantable cardiac defibrillators (ICD), and cardiac resynchronization therapy (CRT) devices, regulate heart rate and rhythm in patients with cardiac conditions. With an aging population, CIED-related complications, especially pacemaker pocket infections, are rising. Risk factors include frailty, older age, and superficial device fixation, while risk mitigation involves larger pocket sizes, submuscular fixation, and absorbable antibacterial envelopes.
View Article and Find Full Text PDFJ Clin Med
December 2024
Division of Cardiovascular Medicine, Tufts Medical Center, Boston, MA 02111, USA.
: Heart failure is the leading cause of hospital admission and mortality. Racial disparities have been demonstrated in various cardiovascular disorders; however, the data for in-hospital outcomes, complications, and procedural rates are limited. : Utilizing the National Inpatient Sample (NIS) database, this retrospective cohort study included adult patients admitted with a principal diagnosis of heart failure.
View Article and Find Full Text PDFCancers (Basel)
January 2025
Department of Radiation Oncology, TUM School of Medicine and Health and Klinikum rechts der Isar, University Hospital of the Technical University of Munich, Ismaninger Straße 22, 81675 Munich, Germany.
Objectives: The present study aimed to compare the tumor growth delay between conventional radiotherapy (CRT) and the spatially fractionated modalities of microbeam radiation therapy (MRT) and minibeam radiation therapy (MBRT). In addition, we also determined the influence of beam width and the peak-to-valley dose ratio (PVDR) on tumor regrowth.
Methods: A549, a human non-small-cell lung cancer cell line, was implanted subcutaneously into the hind leg of female CD1 mice.
Strahlenther Onkol
January 2025
TUM School of Medicine and Health, Department of Radiation Oncology, Technische Universität München (TUM), Klinikum rechts der Isar, Munich, Germany.
Purpose: Increasing life expectancy and advances in cancer treatment will lead to more patients needing both radiation therapy (RT) and cardiac implantable electronic devices (CIEDs). CIEDs, including pacemakers and defibrillators, are essential for managing cardiac arrhythmias and heart failure. Telemetric monitoring of CIEDs checks battery status, lead function, settings, and diagnostic data, thereby identifying software deviations or damage.
View Article and Find Full Text PDFZhonghua Nei Ke Za Zhi
January 2025
Department of Pacing Electrophysiology, the First Affiliated Hospital of Xinjiang Medical University, Urumqi830000, China.
The aim of this study was to assess the frailty status of patients with heart failure undergoing CRT-D and then explore the predictive value of frailty for all-cause mortality and heart failure-related readmissions in these patients. We retrospectively included 374 patients with chronic heart failure who underwent CRT-D treatment at the First Affiliated Hospital of Xinjiang Medical University between June 2020 and June 2024. Based on the Tilburg Debilitation Assessment Scale, 175 patients (46.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!