A birdcage resonant helicon antenna is designed, mounted, and tested in the toroidal device TORPEX. The birdcage resonant antenna is an alternative to the usual Boswell or half-helical antenna designs commonly used for ∼10 cm diameter helicon sources in low temperature plasma devices. The main advantage of the birdcage antenna lies in its resonant nature, which makes it easily operational even at large scales, an appealing feature for the TORPEX device whose poloidal cross section is 40 cm in diameter. With this antenna, helicon waves are shown to be launched and sustained throughout the whole torus of TORPEX. The helicon waves can be launched at low power on a pre-existing magnetron-generated plasma with little effect on the density profiles. The birdcage antenna can also be used alone to produce plasma, which removes the constraint of a narrow range of applied magnetic fields required by the magnetron, opening the way to a new range of studies on TORPEX with the external magnetic field as a control parameter.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0212529DOI Listing

Publication Analysis

Top Keywords

birdcage resonant
12
resonant antenna
8
antenna helicon
8
torpex birdcage
8
birdcage antenna
8
helicon waves
8
waves launched
8
antenna
7
birdcage
5
helicon
5

Similar Publications

Background: Low-field open magnetic resonance imaging (MRI) systems, typically operating at magnetic field strengths below 1 Tesla, has greatly expanded the accessibility of MRI technology to meet a wide range of patient needs. However, the inherent challenges of low-field MRI, such as limited signal-to-noise ratios and limited availability of dedicated radiofrequency (RF) coils, have prompted the need for innovative coil designs that can improve imaging quality and diagnostic capabilities. In this work, we introduce a multimodal axial array resonator and its implementation in a volume coil, or referred to as a coupled stack-up volume coil, to address these challenges in low-field open MRI.

View Article and Find Full Text PDF

MRI of patients with Deep Brain Stimulation (DBS) implants is constrained due to radiofrequency (RF) heating of the implant lead. However, "RF-shimming" parallel transmission (PTX) has the potential to reduce DBS heating during MRI. As part of using PTX in such a "safe mode", maps of the RF transmission field (B1+) are typically acquired for calibration purposes, with each transmit coil excited individually.

View Article and Find Full Text PDF

Fluorine-19 (F) MRI has become an established tool for in vivo cell tracking following ex vivo or in vivo labelling of various cell types with F perfluorocarbons (PFCs). Here, we developed and evaluated novel mouse-specific radiofrequency (RF) hardware for improved dual H anatomical imaging and deep tissue F MR detection of PFCs. Three linearly polarized birdcage RF coils were constructed-a dual-frequency H/F coil, and a pair of single-frequency H and F coils, designed to be used sequentially.

View Article and Find Full Text PDF

Design of multi-row parallel-transmit coil arrays for enhanced SAR efficiency with deep brain electrodes at 3T: an electromagnetic simulation study.

MAGMA

November 2024

School of Biomedical Engineering and Imaging Science, King's College London, 3rd Floor Lambeth Wing, St Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, UK.

Objective: Tissue heating near the implanted deep brain stimulation (DBS) during magnetic resonance imaging (MRI) poses a significant safety constraint. This study aimed to evaluate the performance of parallel transmit (pTx) head transmit radiofrequency (RF) coils in DBS patients, with a focus on excitation fidelity under specific absorption rate (SAR) control for brain imaging at 3T MRI.

Materials And Methods: We employed electromagnetic simulations to assess different coil configurations, including multi-row pTx coils of 16-24 channels arranged in 1, 2, and 3 rows, and compared these to a circularly polarised and pTx birdcage coil using a realistic human model without and with DBS leads and electrodes.

View Article and Find Full Text PDF

A deep brain stimulation-conditioned RF coil for 3T MRI.

Magn Reson Med

March 2025

Institute of Medical Physics and Radiation Protection, Department of Life Science Engineering, TH-Mittelhessen University of Applied Sciences, Giessen, Germany.

Purpose: To develop and test an MRI coil assembly for imaging deep brain stimulation (DBS) at 3 T with a reduced level of local specific absorption rate of RF fields near the implant.

Methods: A mechanical rotatable linearly polarized birdcage transmitter outfitted with a 32-channel receive array was constructed. The coil performance and image quality were systematically evaluated using bench-level measurements and imaging performance tests, including SNR maps, array element noise correlation, and acceleration capabilities.

View Article and Find Full Text PDF