Acute type B aortic dissection following transcatheter mitral valve edge-to-edge repair: a case report.

Eur Heart J Case Rep

Department of Cardiology, Shantou Central Hospital, #114 Waima Road, Jinping District, Shantou City 515031, Guangdong Province, PR China.

Published: September 2024

Background: Transoesophageal echocardiography is rarely reported as a possible cause of aortic dissection during the transcatheter edge-to-edge repair procedure. Herein, we present a case of type B aortic dissection following the transcatheter mitral valve edge-to-edge repair procedure, most likely related to the transoesophageal echocardiography probe.

Case Summary: A 68-year-old Chinese man complained of exertional dyspnoea lasting over 2 years and had been diagnosed with severe mitral regurgitation. He was admitted to our hospital for the treatment of severe mitral regurgitation with transcatheter edge-to-edge repair. One MitraClip XTR (Abbott Vascular) was successfully implanted under the guidance of active transoesophageal echocardiography, and the mitral regurgitation became trace. However, the patient complained of persistent back pain after the treatment, and computed tomography angiography revealed a type B aortic dissection in the descending aorta. After 2 weeks of unsuccessful conservative treatment, he successfully underwent endovascular stenting and was discharged from the hospital. The patient recovered well and remained event free during the 6-month follow-up.

Discussion: Herein, we presented a rare complication following transcatheter mitral valve edge-to-edge repair that was most likely related to the transoesophageal echocardiography probe-type B aortic dissection. We postulated that repetitive flexion of the transoesophageal echocardiography probe led to compression-induced injury to the descending aorta wall at the mid-oesophageal level, which was the most probable aetiology of type B aortic dissection. Although this complication is rare, it is potentially fatal and therefore needs attention.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11368121PMC
http://dx.doi.org/10.1093/ehjcr/ytae424DOI Listing

Publication Analysis

Top Keywords

aortic dissection
24
edge-to-edge repair
20
transoesophageal echocardiography
20
type aortic
16
dissection transcatheter
12
transcatheter mitral
12
mitral valve
12
valve edge-to-edge
12
mitral regurgitation
12
transcatheter edge-to-edge
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!