Automated segmentation of clinical CT scans of the cochlea and analysis of the cochlea's vertical profile.

Heliyon

Department of Otorhinolaryngology and Head & Neck Surgery, Leiden University Medical Center, PO Box 9600, 2300 RC, Leiden, the Netherlands.

Published: August 2024

AI Article Synopsis

  • A study focused on enhancing cochlear implantation techniques by creating a model-free automated algorithm that accurately segments 3D surfaces of the cochlea from CT scans.
  • The algorithm was validated against manually segmented CT scans, demonstrating high accuracy with a 90% area overlap and minimal average distance discrepancy (0.11 mm).
  • Findings suggest that this new approach enables precise quantitative analysis of cochlear anatomy, providing an objective evaluation of the vertical cochlear trajectory, which challenges traditional categorizations based on shape.

Article Abstract

Purpose: Knowledge of the cochlear anatomy in individual patients is helpful for improving electrode selection and placement during cochlear implantation, as well as in surgical planning. The aim of this study was to develop a model-free automated segmentation algorithm to obtain 3D surfaces from clinical computed tomography (CT) scans that describe an individual's cochlear anatomy and can be used to quantitatively analyze the cochlea's vertical trajectory.

Methods: Clinical CT scans were re-oriented and re-sliced to obtain mid-modiolar slices. Using these slices, we segmented the cross-section of the cochlea.

Results: 3D surfaces were obtained for the first 1.5 turns of 648 cochleae. Validation of our algorithm against the manually segmented ground truth obtained from 8 micro-CT scans showed good agreement, with 90 % area overlap and an average distance of 0.11 mm between the segmentation contours. The average cochlear duct length for the basal turn was 16.1 mm along the central path and 22.4 mm along the outer wall. The use of an intrinsic, observer-independent coordinate system and principal component analysis enabled unambiguous quantitative evaluation of the vertical trajectory of the cochlea, revealing only a weak correlation between the symmetry of the commonly used basal turn diameters (B-ratio of A and B diameters) and the profile of the vertical trajectory.

Conclusion: A model-free segmentation algorithm can achieve similar accuracy as previously published methods relying on statistical shapes. Quantitative analysis of the vertical trajectory can replace the categorization into rollercoaster, sloping, or intermediate vertical trajectory types.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11367034PMC
http://dx.doi.org/10.1016/j.heliyon.2024.e35737DOI Listing

Publication Analysis

Top Keywords

vertical trajectory
12
automated segmentation
8
clinical scans
8
cochlea's vertical
8
cochlear anatomy
8
segmentation algorithm
8
basal turn
8
vertical
6
segmentation clinical
4
scans
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!