AI Article Synopsis

  • The study focused on using shear horizontal (SH) guided wave transducers made from near stoichiometric lithium niobate (NSLN) for structural health monitoring in high-temperature environments.
  • The optimized NSLN transducers effectively transmitted and received SH waves across a frequency range of 100-350 kHz, producing strong signals even at 650 °C.
  • The results showed that these transducers had improved defect detection capabilities, with a signal-to-noise ratio of 16.1 dB at high temperatures, highlighting their potential for practical applications in structural monitoring.

Article Abstract

The application of shear horizontal (SH) guided wave transducers in high-temperature structural health monitoring (SHM) is a topic of significant interest across various industrial engineering sectors. In this study, we utilized the novelty piezoelectric crystal of near stoichiometric lithium niobate (NSLN), which exhibited a robust piezoelectric response ( = 77.6 pC/N@room temperature). Next, the pure thickness shear vibration mode through size optimization was designed. It was demonstrated that the NSLN-based ultrasonic guided wave transducers utilizing the optimum mode were proficient in transmitting and receiving pure fundamental SH wave (SH wave) along two orthogonal main directions (0° and 90°) over a wide frequency range (100-350 kHz), exhibiting strong response to the SH wave. Under the driving voltage of 100 V, the signal voltages of the NSLN-based transducer were found to be on the order of 200.3 and 11.8 mV at room temperature and high temperature of 650 °C, respectively. Moreover, the NSLN-based SH transducer showcased its better defect localization ability, and the signal-to-noise ratio (SNR) sensitivity of NSLN-based transducer was evaluated to be 16.1 dB at high temperature of 650 °C. To sum up, the ultrasonic wave transducer based on NSLN crystal demonstrated higher potential applications for in situ SHM under elevated temperatures.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.4c09463DOI Listing

Publication Analysis

Top Keywords

guided wave
12
650 °c
12
nsln-based transducer
12
shear horizontal
8
horizontal guided
8
wave transducer
8
structural health
8
health monitoring
8
wave transducers
8
high temperature
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!