A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and evaluation of a novel user-operated slider-based audiometry method. | LitMetric

Objective: To evaluate a novel user-operated audiometry method allowing users full control in determining their pure-tone hearing thresholds.

Design: Comparative study. Participants were recruited from a hearing clinic after undergoing manual audiometry (six frequencies). They then performed test-retests of a new test (slider audiometry, eight frequencies) and completed the System Usability Scale questionnaire.

Study Sample: 37 adult participants, including 30 hearing-impaired and seven normal-hearing individuals.

Results: Mean (SD) threshold differences for octave frequencies between 250 to 2000 Hz between manual and slider audiometry ranged from -7.8 (6.6) to -5.7 (6.5) dB and were significant. For 4000 and 8000 Hz mean differences were -0.3 (8.4) and 0.0 (9.7) dB and insignificant. Standard deviations ranged from 6.5 to 9.7 dB across six tested frequencies. Slider test-retest mean threshold differences ranged from -1.4 (4.7) to 0.3 (6.0) dB across eight tested frequencies, with standard deviations ranging from 4.1 to 8.5 dB. The average usability score for the slider audiometry was 88.3.

Conclusion: When compared to manual audiometry, the slider audiometry demonstrated validity at 4000 and 8000 Hz but found significantly lower thresholds for octave frequencies between 250 to 2000 Hz. Test-retests of the new method revealed small mean differences and acceptable SDs.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14992027.2024.2396523DOI Listing

Publication Analysis

Top Keywords

slider audiometry
16
novel user-operated
8
audiometry
8
audiometry method
8
manual audiometry
8
audiometry frequencies
8
threshold differences
8
octave frequencies
8
frequencies 250
8
250 2000 hz
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!