Metallurgical defects in metal laser additive manufacturing (LAM) are inevitable due to complex non-equilibrium thermodynamics. A laser ultrasonic system was designed for detecting surface/near-surface defects in the layer-by-layer LAM process. An approach was proposed for ultrasonic imaging of defects based on variable time window intensity mapping with adaptive 2σ threshold denoising. The Gaussian mixture model hypothesis and expectation-maximization algorithm can automatically differentiate between components dominated by defects and background noises, thereby providing an adaptive threshold that accommodates detection environments and surface roughness levels. Results show that the ultrasonic wave reflection at defect boundaries diminishes far-field ultrasonic intensity upon pulsed laser irradiation on surface defects, enabling defect size and location characterization. This method is applicable to LAM samples with a significant surface roughness of up to 37.5 μm. It can detect superficial and near-surface defects down to 0.5 mm in diameter and depth, making it significant for online defect detection in additive manufacturing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11363626PMC
http://dx.doi.org/10.1016/j.pacs.2024.100638DOI Listing

Publication Analysis

Top Keywords

laser ultrasonic
8
based variable
8
variable time
8
time window
8
window intensity
8
intensity mapping
8
mapping adaptive
8
adaptive 2σ
8
additive manufacturing
8
surface roughness
8

Similar Publications

Evaluation of bacterial biofilm, smear layer, and debris removal efficacy of a hydro-dynamic cavitation system with physiological saline using a new ex vivo model: a CLSM and SEM study.

BMC Oral Health

January 2025

Division of Endodontics, Department of Oral Biological and Medical Sciences, Faculty of Dentistry, University of British Columbia, 2199 Wesbrook Mall, Vancouver, British Columbia, V6T 1Z3, Canada.

Introduction: To evaluate the bacterial biofilm, smear layer and debris removal efficacy of a hydro-dynamic cavitation system with physiological saline using a new ex vivo model.

Methods: Seventy-five dentin discs were prepared from fifty-four extracted teeth. Seventy-five artificial root sockets were prepared.

View Article and Find Full Text PDF

Ultrasound can improve the quality of finished products by reducing porosity and enhancing microstructure in selective laser melting, directed energy deposition, and laser beam welding. This study evaluates the efficiency of ultrasound produced by a pulsed laser via the optoacoustic effect. A quantitative model of collapse of vapor-gas bubbles has been developed under the conditions of ultrasonic treatment at near resonance frequencies.

View Article and Find Full Text PDF

Assessment of Corrosion and Cavitation Resistance of Laser Remelted GX40CrNiSi25-20 Cast Stainless Steel.

Materials (Basel)

December 2024

Department of Materials and Fabrication Engineering, Politehnica University Timisoara, Bulevardul Mihai Viteazul nr.1, 300222 Timișoara, Romania.

This paper explores the enhancement of cavitation and corrosion resistance in cast stainless steel through laser beam surface remelting. The influence of laser treatment on material properties was assessed by analyzing the microstructure using optical microscopy, electron microscopy, and X-ray diffraction. Cavitation erosion was evaluated in tap water using an ultrasonic vibration setup, following ASTM G32-2016 standards.

View Article and Find Full Text PDF

Recently, Organ-on-a-Chip (OoC) platforms have arisen as an increasingly relevant experimental tool for successfully replicating human physiology and disease. However, there is a lack of a standard technology to monitor the OoC parameters, especially in a non-invasive and label-free way. Photoacoustic (PA) systems can be considered an alternative and accurate assessment method for OoC platforms.

View Article and Find Full Text PDF

This study aimed to develop ultrasonically-assisted, alcohol-free, and noncorrosive aqueous zein/turmeric essential oil (TEO)-loaded nanoemulsions (NEs) to stimulate pullulan/carboxymethyl chitosan (P/CMCS)-based edible films for mango fruit preservation. The influence of innovative sonicated zein/TEO-based NEs (ZTNEs) as nanofillers on the physico-mechanical characteristics of the resulting P/CMCS edible films was investigated. A stable and well-dispersed ZTNE was achieved using 20 % zein with 10 min of ultrasound treatment, leading to a reduced droplet size (194.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!