Introduction Heart failure (HF) poses a substantial and escalating medical and economic challenge, marked by significant morbidity and mortality. It stands as the primary cause of hospital admissions among the elderly, contributing significantly to healthcare expenditures in developed nations. Evaluating cardiac and pulmonary function remains challenging, necessitating careful interpretation to mitigate misdiagnosis and inappropriate treatment. Remote monitoring has emerged as a preventive strategy to curb HF-related hospitalizations, emphasizing the importance of early detection of impending acute HF decompensation. Implantable cardiac defibrillators (ICDs) capture various parameters, including heart rhythm, pacing percentages, thoracic impedance, and physical activity. Objective In this study, we aim to investigate the effectiveness of HeartLogic (Boston Scientific, Marlborough, Massachusetts) parameters in accurately distinguishing HF patients from individuals with alternative diagnoses. Methods This cross-sectional study was conducted at Cabell Huntington Hospital, St. Mary's Medical Center in Huntington, West Virginia, between 2021 and 2022. The study involved a retrospective chart review of electronic medical records, approved by the institutional review board, encompassing patients aged >18 admitted with Heartlogic-capable devices. The analysis included demographic variables, admission and discharge diagnoses, length of hospital stays, health literacy index, and thoracic impedance. Results Of the initially included 26 patients, 19 met all inclusion criteria. The demographic profile highlighted a predominantly older population with a male preponderance and a notable incidence of congestive heart failure (CHF). Physiological changes, particularly in thoracic impedance and the HeartLogic Index, demonstrated significant alterations. Logistic regression analysis revealed that changes in health literacy index and thoracic impedance significantly contributed to predicting the change in CHF diagnosis. Conclusion This study, conducted in a rural setting, demonstrates the capability of the HeartLogic algorithm in predicting HF events, providing valuable insights into its utility in diverse clinical environments. The findings emphasize the potential of this technology to enhance diagnostic accuracy and improve patient outcomes. Despite inherent limitations, this analysis contributes unique perspectives, particularly in the context of a specific and underexplored rural population in West Virginia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11365457PMC
http://dx.doi.org/10.7759/cureus.65949DOI Listing

Publication Analysis

Top Keywords

thoracic impedance
16
heart failure
12
study conducted
8
west virginia
8
health literacy
8
literacy thoracic
8
study
5
enhancing heart
4
failure diagnosis
4
diagnosis accuracy
4

Similar Publications

Cardiac implantable electronic devices and their integrated thoracic impedance sensors have been used to detect sleep apnea for over a decade now. Despite their usage in daily clinical practice, there are only limited data on their diagnostic accuracy. AIRLESS and UPGRADE were prospective investigator-driven trials meant to validate the AP scan (Boston Scientific, Marlborough, MA, USA) in heart failure cohorts.

View Article and Find Full Text PDF

Daily Measurements from Cardiac Implantable Electronic Devices to Assess Health Status.

Diagnostics (Basel)

December 2024

Department of Cardiology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.

Cardiac implantable electronic devices (CIEDs) such as pacemakers and implantable cardioverter-defibrillators (ICDs) are increasingly used in the aging population. Modern CIEDs perform daily measurements, mainly aimed at discovering early signs of battery depletion or electrode dysfunction. Changes in thresholds, intracardiac signals, and pacing impedances can be caused by exacerbation of existing conditions or novel clinical problems.

View Article and Find Full Text PDF

This study aims to assess the outcomes of therapeutic options for aortic arch pathologies by comparing thoracic endovascular aortic repair (TEVAR) with open arch replacement (OAR) using woven polyester grafts from a mechanical and biomechanical perspective, with emphasis on ex vivo perfused human thoracic aortas reproducing heart rate and stroke volume conditions. Eleven non-diseased thoracic aortas from human cadavers were divided into TEVAR (n=5) and OAR (n=6) and tested using a custom-built mock circulation loop. Pressure, diameter, and stroke volume were monitored during perfusion before and after the intervention.

View Article and Find Full Text PDF

Background: Lung cancer is a pathology with an important incidence. It is a multifactorial disease characterized by epigenetic and nutritional factors. Indeed, there is a strong association between adipose tissue and the pulmonary system, and low-grade inflammation of obese and/or overweight subjects have a pivotal role in lung cancer establishment.

View Article and Find Full Text PDF

Patients with fatty acid oxidation disorders (FAODs) experience muscle symptoms due to impaired ATP metabolism and the toxicity of accumulated mitochondrial FAO substrates or intermediates, especially during catabolic states. A major issue is the absence of specific and sensible biomarkers to evaluate metabolic equilibrium. The relationship between cardiac output (Q) and oxygen consumption (VO) during incremental exercise (dQ/dVO) provides an indirect surrogate of mitochondrial function.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!