Percutaneous transvalvular microaxial flow pump is underused in infarct-related cardiogenic shock: pros and cons.

EuroIntervention

Institut für Herzinfarktforschung, Klinikum Ludwigshafen, Ludwigshafen, Germany.

Published: September 2024

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11352518PMC
http://dx.doi.org/10.4244/EIJ-E-24-00033DOI Listing

Publication Analysis

Top Keywords

percutaneous transvalvular
4
transvalvular microaxial
4
microaxial flow
4
flow pump
4
pump underused
4
underused infarct-related
4
infarct-related cardiogenic
4
cardiogenic shock
4
shock pros
4
pros cons
4

Similar Publications

Background: Mitral annular calcification (MAC) is characterized by severe calcification of mitral annulus and might be associated with both mitral regurgitation and stenosis. It is technically challenging for both surgical and percutaneous approach and is burdened by high mortality.

Case Summary: The present case report describes a complex case of mitral steno-insufficiency (baseline transvalvular gradient = 5 mmHg, effective regurgitant orifice area 0.

View Article and Find Full Text PDF

Temporary microaxial transvalvular left ventricular assist device for post-myocardial infarction ventricular septal rupture: Bridging a paradigm shift.

JTCVS Tech

December 2024

Department of Thoracic and Cardiovascular Surgery, Kaufman Center for Heart Failure Treatment and Recovery, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio.

Objective: To characterize the clinical courses and outcomes of patients presenting with post-myocardial infarction (MI) ventricular septal rupture (VSR) receiving temporary microaxial transvalvular left ventricular assist device (tVAD) support.

Methods: Between December 2019 and July 2023, 10 consecutive patients presented with a post-MI VSR. All 10 patients received a tVAD.

View Article and Find Full Text PDF

[Purpose] To examine the effectiveness of acute and outpatient cardiac rehabilitation for severe intensive care unit (ICU)-acquired weakness. [Participant and Methods] A 79-year-old woman, diagnosed with takotsubo syndrome. A percutaneous catheter-based transvalvular left ventricular assist device was used from day 2 to day 8, extracorporeal membrane oxygenation from day 3 to day 9, and inotropic support from day 1 to day 15.

View Article and Find Full Text PDF

[Mid- and long-term outcomes of percutaneous balloon mitral valvuloplasty guided solely by echocardiography].

Zhonghua Yi Xue Za Zhi

October 2024

Department of Structural Heart Disease, National Center for Cardiovascular Disease, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College/National Health Commission Key Laboratory of Cardiovascular Regeneration Medicine/State Key Laboratory of Cardiovascular Disease/Key Laboratory of Innovative Cardiovascular Devices, Chinese Academy of Medical Sciences/National Clinical Research Center for Cardiovascular Diseases, Beijing 100037, China.

Article Synopsis
  • A study evaluated the long-term clinical outcomes of percutaneous balloon mitral valvuloplasty (PBMV) in 71 patients with moderate to severe mitral stenosis, all guided by echocardiography at a Chinese hospital from 2016 to 2022.* -
  • The procedure had a success rate of 98.6%, with significant improvements in mitral valve function, reflected by a decrease in the pressure gradient and an increase in valve area postoperatively.* -
  • During an average follow-up of nearly 50 months, most patients had favorable outcomes, though a few experienced new mild to moderate mitral regurgitation and some required further surgical intervention.*
View Article and Find Full Text PDF
Article Synopsis
  • - Balloon aortic valvuloplasty (BAV) is a procedure used for patients with severe aortic valve stenosis, either as preparation for trans-catheter aortic valve replacement (TAVR) or alone in certain cases; the study focused on the newly available Mammoth balloon catheter (BC) used in this context.
  • - A retrospective analysis was conducted on patients treated with the Mammoth BC at a hospital in Milan, where technical success was defined by the ability to successfully deploy and inflate the catheter without significant complications like injury or stroke.
  • - The results showed a 100% technical success rate in 121 procedures with no complications attributed to the Mammoth BC; however, some patients in the stand-alone group
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!