Vascular function is impaired in patients with aortic valve stenosis (AS). The impact of transcatheter aortic valve implantation (TAVI) on endothelial function is inconclusive so far. Therefore, we sought to assess the short-term influence of TAVI on endothelial dysfunction in patients with AS. We recruited 47 patients (76.6 % male, 80.04 years old) with AS scheduled for TAVI. Endothelial function was assessed by fingertip reactive hyperemia peripheral arterial tonometry (RH-PAT). Measurements were conducted one day before and three days after TAVI. Patients were grouped according to RH-PAT change after TAVI. Overall, RH-PAT measurements did not significantly improve after TAVI (Reactive Hyperemia Index: 1.5 vs 1.6, p = 0.883; logarithm of the Reactive Hyperemia Index: 0.44 vs. 0.49, p = 0.523). Interestingly, patients with no RH-PAT improvement after TAVI displayed a more severe AS and had lower blood pressure after TAVI. This might be due to a more disturbed blood flow in patients with a smaller aortic valve area and higher peak aortic valve velocity. The relationship between AS severity, endothelial dysfunction and TAVI has to be investigated in future research that apply longitudinal study designs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mvr.2024.104735DOI Listing

Publication Analysis

Top Keywords

aortic valve
20
endothelial function
12
tavi endothelial
12
reactive hyperemia
12
tavi
9
transcatheter aortic
8
valve implantation
8
patients aortic
8
endothelial dysfunction
8
rh-pat measurements
8

Similar Publications

Purpose: There are limited reports on the potential link between Lp(a) and ARDM. Thus, we examined the relationship between Lp(a) and ARDM among hypertensive patients.

Methods: We used echocardiography to measure ARDM in 513 consecutively hospitalized patients.

View Article and Find Full Text PDF

Objectives: Screening for obstructive coronary artery disease (CAD) with coronary computed tomography angiography (CCTA) could prevent unnecessary invasive coronary angiography (ICA) procedures during work-up for trans-catheter aortic valve implantation (TAVI). CT-derived fractional flow reserve (CT-FFR) improves CCTA accuracy in chest pain patients. However, its reliability in the TAVI population is unknown.

View Article and Find Full Text PDF

Background: Takayasu arteritis is a large-vessel vasculitis, in addition to giant cell arteritis. Various post-operative complications associated with the cardiac macrovasculature have been reported. Detachment of the prosthetic valve, pseudoaneurysm formation, and dilatation of the aortic root are well-known post-operative complications associated with vasculitis syndromes, including Takayasu arteritis.

View Article and Find Full Text PDF

Background: Despite advancements in valve implantation devices, vascular access complications (VAC) remain a significant cause of morbidity and mortality for those undergoing transcatheter aortic valve replacement (TAVR). We describe pre-operative imaging analysis of the aortoiliac and femoral arterial beds using the TransAtlantic intersociety consensus (TASC) score, ilio-femoral tortuosity, and procedural characteristics to identify anatomic risk factors predictive of VAC in TAVR.

Methods: Consecutive patients undergoing TAVR from 2012 to 2022 at a single North Dakota hospital were retrospectively reviewed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!