A colorimetric assay for Neospora caninum utilizing the loop-mediated isothermal amplification technique.

Res Vet Sci

College of Life Sciences and Engineering, Foshan University, Foshan 528225, Guangdong Province, China; College of Veterinary Medicine, Southwest University, Chongqing 400715, China. Electronic address:

Published: November 2024

Neospora caninum (N. caninum) is a protozoan parasite that poses a serious risk to livestock by infecting various domestic and wild animals. Loop-Mediated Isothermal Amplification (LAMP) offers a cost-effective, highly sensitive, and specific method for detecting protozoan parasites. This study aims to develop a precise, rapid, and visually assessable colorimetric LAMP method, improving on traditional techniques. We employed a rigorous screening process to identify the optimal primer set for this experiment. Subsequently, we fine-tuned the LAMP reaction at 65 °C for 40 min with 270 μmol/L neutral red. We then confirmed the specificity of primers for N. caninum through experimental validation. The LAMP method demonstrated a lower detection limit compared to traditional Polymerase Chain Reaction (PCR) techniques. While LAMP offers clear advantages, the prevalence of DNA detected in 89 sheep serum and 59 bovine serum samples using the nested PCR method was 3.37 % (3/89) and 1.69 % (1/59), respectively. In contrast, when the LAMP method was employed, the prevalence of detected DNA rose to 5.61 % (5/89) for sheep and 3.38 % (2 /59) for bovine. A comparison of two molecular assays using the intragroup correlation coefficient (ICC) resulted in a value of 0.999 (95 % CI: 0.993-0.996, p < 0.001), indicating the LAMP method is in the "better" range according to James Lee's categorization. The LAMP technique, optimized with specific primers of N. caninum and neutral red dye, not only exhibited higher sensitivity but also provided convenience over conventional PCR methods, highlighting its potential for on-site applications and cost-effective field detection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.rvsc.2024.105395DOI Listing

Publication Analysis

Top Keywords

lamp method
12
neospora caninum
8
loop-mediated isothermal
8
isothermal amplification
8
lamp offers
8
lamp
6
method
5
colorimetric assay
4
assay neospora
4
caninum
4

Similar Publications

Objectives: Fundoscopy is crucial in the emergency department to identify or rule out serious ocular and neurological conditions. Despite its clinical importance, fundoscopy is often omitted due to the technical challenges associated with traditional direct ophthalmoscopy, particularly for non-ophthalmologists. This study examines emergency physicians' practices, confidence levels, and training related to various modalities of fundoscopy including traditional direct ophthalmoscopes, binocular indirect ophthalmoscopes, panoptic ophthalmoscopes, slit lamp fundoscopy and fundus cameras; and explores the potential role of alternative modalities, such as fundus cameras, in Canadian emergency departments.

View Article and Find Full Text PDF

Assessment of the impact of different SARS-CoV-2 inactivation operations on colistin sulfate plasma concentration results.

BMC Infect Dis

January 2025

Department of Cardiac Surgery, Second Hospital of Hebei Medical University, No.215 of Heping West Road,Xinhua District, Shijiazhuang, 050000, China.

Objective: To evaluate the effects of different SARS-CoV-2 inactivation methods on the blood concentration of colistin sulfate.

Methods: A colistin sulfate reference substance, a quality control plasma sample, and a clinically measured sample were transferred and heated in a 56 °C water batch for 30 min or irradiated under an ultraviolet (UV) lamp for 60 min to examine the stability of the reference solution and quality control plasma sample. Statistical analysis was conducted for the concentration of the clinically measured sample before and after inactivation with the intraclass correlation coefficient (ICC) method, the Passing-Bablok regression, and the Bland-Altman analysis.

View Article and Find Full Text PDF

Background: Large language models have shown remarkable efficacy in various medical research and clinical applications. However, their skills in medical image recognition and subsequent report generation or question answering (QA) remain limited.

Objective: We aim to finetune a multimodal, transformer-based model for generating medical reports from slit lamp images and develop a QA system using Llama2.

View Article and Find Full Text PDF

Nanoparticle-mediated light-driven LAMP combined with test strips for sensitive and rapid visual detection of antibiotic resistance genes.

J Hazard Mater

December 2024

State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; International Joint Laboratory on Food Safety, Institute of Analytical Food Safety, School of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu 214122, China. Electronic address:

Antibiotic resistance genes (ARGs) are markers of drug-resistant pathogens, monitoring them contributes to prevent resistance to drugs. The detection methods for ARGs including PCR and isothermal amplification are sensitive and selective. However, it may take several hours or cannot be used on spot.

View Article and Find Full Text PDF

High-Definition, Video-Rate Triple-Channel NIR-II Imaging Using Shadowless Lamp Excitation and Illumination.

ACS Nano

January 2025

State Key Laboratory of Extreme Photonics and Instrumentations, Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Hangzhou 310058, China.

Multichannel imaging in the second near-infrared (NIR-II) window offers vital and comprehensive information for complex surgical environments, yet a simple, high-quality, video-rate multichannel imaging method with low safety risk remains to be proposed. Centered at the superior NIR-IIx window of 1400-1500 nm, triple-channel imaging coordinated with 1000-1100 and 1700-1880 nm (NIR-IIc) achieves exceptional clarity and an impressive signal-to-crosstalk ratio as high as 22.10.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!