Indoor volatile organic compounds (VOCs) pose considerable health hazards. However, research on hazardous VOCs in Chinese residences has been conducted on a limited spectrum. This study used Monte Carlo simulations with data from Beijing, Shanghai, and Shenzhen to assess VOC health risks in Chinese homes. We identified high-risk VOCs and analyzed the impact of geographic location, age group, activity duration, and inhalation rate on VOC exposure, including lifetime risks. Formaldehyde, acrolein, naphthalene, and benzene posed the highest risks. Notably, acrolein made the leading contribution to non-cancer risks across all megacities. Naphthalene had elevated cancer and non-cancer risks in Shenzhen. This study highlights the need to investigate acrolein and naphthalene, which are currently unregulated but pose substantial health risks. The cumulative cancer risk (TCR) decreases from adults to children, while the cumulative non-cancer risk (HI) is higher for children. In all cities, the average TCR for adults exceeds the tolerable threshold of 10, and the average HI values surpass the safety threshold of 1. Nearly 100 % of the population faces a lifetime cancer risk above 10, and over 71 % face a non-cancer risk exceeding 10 (tenfold the benchmark). This study underscores the critical need for developing control strategies tailored to VOCs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhazmat.2024.135630DOI Listing

Publication Analysis

Top Keywords

volatile organic
8
organic compounds
8
health risks
8
acrolein naphthalene
8
non-cancer risks
8
cancer risk
8
non-cancer risk
8
risks
6
identifying high-risk
4
high-risk volatile
4

Similar Publications

The development of probes for the efficient detection of volatile organic compounds is crucial for both human health protection and environmental monitoring. In this study, we successfully synthesized a ratiometric fluorescent sensing material [Eu-UiO-67 (1:1)], featuring dual-emission fluorescence peaks via a one-pot method. This material demonstrated exceptional ratiometric fluorescence recognition properties for liquid styrene and isoprene, achieving low limit of detections (LODs) of 6.

View Article and Find Full Text PDF

Surface Modifications and Antifungal Efficacy of Origanum Oil Incorporation in Denture-based Materials: An Study.

J Contemp Dent Pract

September 2024

Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, Rio Grande do Sul, Brazil; Department of Dentistry, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands, ORCID: https://orcid.org/0000-0002-5166-8233.

Aim: This study aimed to assess if the addition of origanum oil to denture materials could decrease microorganisms counts and biofilm formation without changing their mechanical/surface properties.

Materials And Methods: A total of 66 resilient denture liner discs (SoftConfort, Dencril Comércio de Plásticos Ltda, SP, Brazil) were prepared with fixed dimensions of 10 × 3 mm for biofilm assay ( = 36) and 12 × 2 mm for sorption-solubility tests ( = 30) containing three oil concentrations - 0, 2.5 and 5%, thereby = 12 per each group samples for biofilm assay and = 10 per each group for sorption-solubility test respectively.

View Article and Find Full Text PDF

Non-volatile electronic memory elements are very attractive for applications, not only for information storage but also in logic circuits, sensing devices and neuromorphic computing. Here, a ferroelectric film of guanine nucleobase is used in a resistive memory junction sandwiched between two different ferromagnetic films of Co and CoCr alloys. The magnetic films have an in-plane easy axis of magnetization and different coercive fields whereas the guanine film ensures a very long spin transport length, at 100 K.

View Article and Find Full Text PDF

Liquid cell transmission electron microscopy (LCTEM) is a powerful technique for investigating crystallisation dynamics with nanometre spatial resolution. However, probing phenomena occurring in liquids while mixing two precursor solutions has proven extremely challenging, requiring sophisticated liquid cell designs. Here, we demonstrate that introducing and withdrawing solvents in sequence makes it possible to maintain optimal imaging conditions while mixing liquids in a commercial liquid cell.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?