Purpose: This study aimed to examine and analyze the presence of sexual dimorphism and symmetry/asymmetry in fixed cadaveric heads and their contributions to clinical practice.
Methods: Measurements were conducted on 6 cadavers and 24 fixed cadaveric heads (n = 30) using a digital microcaliper to assess cranial dimensions, including surgical landmarks, facial index (FI), orbital index (OI), and the danger triangle of the face, offering crucial references for surgeons during surgical interventions.
Results: Analyses were conducted on cadavers consisting of 10 females (33.3%) and 20 males (66.7%). Males demonstrated significantly higher values than females in terms of Zy-Zy (Zy = Zygion), nasal body, and width/length of the columella. Hyperleptoprosop types were the most frequently observed, followed by the leptoprosop type. Females exhibited megaseme characteristics according to OI on both sides. Additionally, the danger triangle of the face was greater in males compared than in females, suggesting a higher risk of infection in this region among males.
Conclusion: The observed sex differences in facial and nasal dimensions, along with facial indices, are crucial for customizing surgical procedures to individual patients. For example, the greater distance in the danger triangle among males highlights the importance of considering anatomical variations to avoid complications, such as septic cavernous sinus thrombosis. Integrating these measurements into preoperative planning can enhance the precision of facial reconstruction and aesthetic surgeries, thereby improving patient outcomes and safety.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00276-024-03474-y | DOI Listing |
Bioengineering (Basel)
January 2025
Research & Development, Aesculap AG, 78532 Tuttlingen, Germany.
Instability remains one of the most common indications for revision after total knee arthroplasty. To gain a better understanding of how an implant will perform in vivo and support surgeons in selecting the most appropriate implant design for an individual patient, it is crucial to evaluate the implant constraint within clinically relevant ligament and boundary conditions. Therefore, this study investigated the constraint of three different implant designs (symmetrical implants with and without a post-cam mechanism and an asymmetrical medial-stabilized implant) under anterior-posterior shear forces and internal-external rotation moments at different flexion angles in human cadaveric knees using a six-degrees-of-freedom joint motion simulator.
View Article and Find Full Text PDFAnn Neurosci
January 2025
Government Medical College, Bhadradri, Kothagudem, Telangana, India.
Background: Taylor and Palmer introduced an angiosome (vascular) concept in reconstructive plastic surgery in 1987. The angiosome is considered a segment of a nerve (cranial or peripheral nerve) supplied by a primary source of blood vessels.
Purpose: To observe the arteries supplying the vestibulocochlear nerves (VIII) from the brainstem till their termination.
J Foot Ankle Surg
January 2025
Universitätsklinikum Carl Gustav Carus an der TU Dresden, Fetscherstr. 74, 01307 Dresden, Germany.
Introduction: With the increased use of computed tomography scans in cases with trimalleolar ankle fractures, bone fragments between the posterior malleolus and the rest of the articular surface tibial plafond surface - described as intercalary fragments (ICFs) - can be recognized. The aim of this study was to determine the ICF size threshold for a significant change in the pressure distribution at the ankle joint, having a considerable impact on the remaining cartilage of the joint.
Design And Methods: Eight human cadaveric lower legs were used, and a posterior malleolus Bartoniček/Rammelt II fracture was created with sequential 2 mm, 4 mm, 6 mm, and 8 mm ICFs.
Surg Innov
January 2025
Department of Neurosurgery, Istanbul University, Faculty of Medicine, Istanbul, Turkey.
Objective: The endoscopic transsphenoidal approach is commonly used for sellar and suprasellar pathologies. However, reaching above the diaphragma sella, especially for posterosuperior and retrocavernous orientation, still poses some challenges. We designed and developed a steerable tip suction cannula (STSC) that has distinct leverage for endoscopic resection of such pathologies.
View Article and Find Full Text PDFProc Inst Mech Eng H
January 2025
Institute of Medical and Biological Engineering, University of Leeds, Leeds, UK.
Subject-specific finite element models of knee joint contact mechanics are used in assessment of interventions and disease states. Cartilage thickness distribution is one factor influencing the distribution of pressure. Precision of cartilage geometry capture varies between imaging protocols.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!