In this study, an individualized and stable passive-control lower-limb exoskeleton robot was developed. Users' joint angles and the center of pressure (CoP) of one of their soles were input into a convolutional neural network (CNN)-long short-term memory (LSTM) model to evaluate and adjust the exoskeleton control scheme. The CNN-LSTM model predicted the fitness of the control scheme and output the results to the exoskeleton robot, which modified its control parameters accordingly to enhance walking stability. The sole's CoP had similar trends during normal walking and passive walking with the developed exoskeleton; the-coordinates of the CoPs with and without the exoskeleton had a correlation of 91%. Moreover, electromyography signals from the rectus femoris muscle revealed that it exerted 40% less force when walking with a stable stride length in the developed system than when walking with an unstable stride length. Therefore, the developed lower-limb exoskeleton can be used to assist users in achieving balanced and stable walking with reduced force application. In the future, this exoskeleton can be used by patients with stroke and lower-limb weakness to achieve stable walking.

Download full-text PDF

Source
http://dx.doi.org/10.1088/2057-1976/ad686fDOI Listing

Publication Analysis

Top Keywords

lower-limb exoskeleton
12
individualized stable
8
exoskeleton
8
exoskeleton robot
8
control scheme
8
stride length
8
length developed
8
stable walking
8
walking
7
stable
5

Similar Publications

Lower limb exoskeletons serve multiple purposes, like supporting and augmenting movement. Biomechanical models are practical tools to understand human movement, and motor control. This paper provides an overview of these models and a comprehensive review of the current applications of them in assistive device development.

View Article and Find Full Text PDF

Purpose: To assess physiological metrics during the use of a commercially available bilateral active ankle exoskeleton during a challenging military-relevant task and if use of the exoskeleton during this task influences: metabolic load, physiological measures or rate of perceived exertion.

Methods: Nine healthy volunteers (5M, 4F) completed this randomized cross-over design trial, with a baseline visit and two randomized test sessions (with/without the exoskeleton). Variables included impact on time to exhaustion during walking on a treadmill at varying speeds and gradients (0-15%) at 26.

View Article and Find Full Text PDF

Exoskeleton Robot Training in Two Patients with an Electrical Burn and Septic Arthritis: A Case Report.

J Burn Care Res

January 2025

Department of Rehabilitation Medicine, Hangang Sacred Heart Hospital, College of Medicine, Hallym University, Seoul, Korea.

Septic arthritis (SA) are rare in patients with burns, but delayed treatment can result in irreversible joint destruction. Early diagnosis and immediate treatment are necessary to prevent joint destruction. Robot training in patients with musculoskeletal diseases and burns, can improve joint range of motion (ROM), muscle strength, and lower extremity function.

View Article and Find Full Text PDF

Predicting lower body joint moments and electromyography signals using ground reaction forces during walking and running: An artificial neural network approach.

Gait Posture

January 2025

Department of Biomechanics and Center for Research in Human Movement Variability, University of Nebraska at Omaha, Omaha, NE 68182, USA; Department of Surgery and Research Service, Nebraska-Western Iowa Veterans Affairs Medical Center, Omaha, NE 68105, USA. Electronic address:

Background: This study leverages Artificial Neural Networks (ANNs) to predict lower limb joint moments and electromyography (EMG) signals from Ground Reaction Forces (GRF), providing a novel perspective on human gait analysis. This approach aims to enhance the accessibility and affordability of biomechanical assessments using GRF data, thus eliminating the need for costly motion capture systems.

Research Question: Can ANNs use GRF data to accurately predict joint moments in the lower limbs and EMG signals?

Methods: We employed ANNs to analyze GRF data and to use them to predict joint moments (363-trials; 4-datasets) and EMG signals (63-trials; 2-datasets).

View Article and Find Full Text PDF

Lower-limb exoskeletons have demonstrated great potential for gait rehabilitation in individuals with motor impairments; however, maintaining human-exoskeleton coordination remains a challenge. The coordination problem, referred to as any mismatch or asynchrony between the user's intended trajectories and exoskeleton desired trajectories, leads to sub-optimal gait performance, particularly for individuals with residual motor ability. Here, we investigate the virtual energy regulator (VER)'s ability to generate coordinated locomotion in lower limb exoskeleton.