Heavily Labeled Signal Probe for Electrogenerated Chemiluminescence Peptide-Based Biosensing of Matrix Metalloproteinase 2.

Chem Asian J

Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi' an, 710119, P. R. China.

Published: December 2024

AI Article Synopsis

  • The growth of electrogenerated chemiluminescence (ECL) biosensing highlights the importance of accurate biomarker detection, especially using peptide-based signal probes with high efficiency.
  • A novel signal probe was created using an Ir(III) complex labeled with streptavidin (Ir1-SA) for detecting matrix metalloproteinase 2 (MMP-2), showing sensitivity in the range of 5 to 100 ng/mL.
  • The study introduced new detection modes for MMP-2, suggesting that the order of enzymatic cleavage and signal transmission can enhance sensitivity, aiding early disease diagnosis.

Article Abstract

The field of electrogenerated chemiluminescence (ECL) biosensing has witnessed remarkable growth, emphasizing the need for precise detection of biomarkers. The synthesis approach of peptide-based signal probe with high recognition ability and high ECL efficiency is a significant issue in the ECL biosensing. Here, a heavily labeled signal probe was synthesized for ECL peptide-based biosensing tactic by using a new aldehyde bearing cyclometalated Ir(III) complex ([Ir(bt)(bpy-CHO)PF (bt=2-phenylbenzothiazole, bpy-CHO=4'-methyl-[2,2'-bipyridine]-4-carbaldehyde, denoted as Ir1) as ECL signal reagent and streptavidin (SA) as carrier protein. One ECL peptide-based biosensing method was exemplified for the detection of matrix metalloproteinase 2 (MMP-2) by using Ir1 labeled SA (SA-Ir1) as heavily labeled signal probe and biotinylated peptide as molecular recognition substrate. MMP-2 was sensitively detected in the range from 5 to 100 ng/mL with a detection limit of 1.5 ng/mL. Importantly, two detection modes differing in the order of cleavage recognition by MMP-2 and signal transduction with SA-Ir1 were compared for the first time. First cleavage and second signal transduction were proposed to be beneficial to sensitive detection of target, which provides some ideas for biomarker diagnostics in disease screening at an early stage.

Download full-text PDF

Source
http://dx.doi.org/10.1002/asia.202400743DOI Listing

Publication Analysis

Top Keywords

signal probe
16
heavily labeled
12
labeled signal
12
peptide-based biosensing
12
electrogenerated chemiluminescence
8
matrix metalloproteinase
8
ecl biosensing
8
ecl peptide-based
8
signal transduction
8
signal
7

Similar Publications

Molecular beacon (MB) probes have been extensively used for nucleic acid analysis. However, MB probes fail to hybridize with folded DNA or RNA. Here, we demonstrate that MB probes equipped with extra sequences complementary to the analyte, named 'tail', can increase the signal-to-background ratio by ∼40-fold and hybridization rates by ∼800-fold compared to conventional MB probes.

View Article and Find Full Text PDF

Inflammatory bowel disease (IBD) with the two predominant endophenotypes-Crohn's disease (CD) and ulcerative colitis (UC)-represents a group of chronic gastrointestinal inflammatory conditions. Since most genetic associations with IBD are often limited to independent subtypes, we reported a genome-wide association study (GWAS) cross-trait analysis combined with CD and UC to enhance statistical power. Initially, we detected 256 association signals at 54 genomic susceptibility loci and further characterized the functionality of variants within these regions.

View Article and Find Full Text PDF

() is a major pathogenic bacterium responsible for bacterial foodborne diseases, making its rapid, specific, and accurate detection crucial. In this study, we develop a ratiometric biosensor based on the recombinase polymerase amplification-clustered regularly interspaced short palindromic repeats/CRISPR associated protein 12a (RPA-CRISPR/Cas12a) system and Eu-metal-organic framework (Eu-MOF) fluorescent nanomaterials for the high-sensitivity detection of , combining with RPA for efficient isothermal amplification, this sensor enhances specificity and sensitivity by utilizing the target activation of CRISPR/Cas12a. The Eu-MOF serves a dual function, providing stable red fluorescence as a reference signal and adsorbing FAM-labeled probes for fluorescence quenching, forming a dual-signal system that significantly reduces background interference.

View Article and Find Full Text PDF

Afterglow luminescence provides ultrasensitive optical detection by minimizing tissue autofluorescence and increasing the signal-to-noise ratio. However, due to the lack of suitable unimolecular afterglow scaffolds, current afterglow agents are nanocomposites containing multiple components with limited afterglow performance and have rarely been applied for cancer theranostics. Herein, we report the synthesis of a series of oxathiine-containing donor-acceptor block semiconducting polymers (PDCDs) and the observation of their high photoreactivity and strong near-infrared (NIR) afterglow luminescence.

View Article and Find Full Text PDF

Objective: To describe application scenarios of a mobile device that provides a practical means for showcasing potential hearing aid benefits.

Design: A prototype of a hearing aid demonstrator based on circumaural headphones and a mobile signal processing platform was developed, providing core functions of a hearing aid, including several gain presets, in a hygienic, robust, and easy-to-use form factor. Speech intelligibility outcomes with the demonstrator and broadband level adaptations as potential fitting references were compared to outcomes with the own hearing aids of hearing-impaired participants.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!