A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Percutaneous Sacroiliac Screw Fixation: A Modified Screw Insertion Method Using Just 2 Fluoroscopy Views. | LitMetric

Objectives: Percutaneous sacroiliac screw fixation (PSSF) is a well-defined method of surgery to fix unstable fractures of the pelvic ring with fewer post-surgical complications. However, the complex anatomy of the mentioned area makes PSSF a formidable challenge. The present study aimed to investigate a modified screw insertion method using two views of fluoroscopy X-ray instead of the prior three views to reduce the duration of operations and radiation exposures.

Methods: The present study was performed on 10 radiopaque plastic pelvic models (including 20 half pelvis) during simulated surgical procedures. Of the 20 screws, 10 were inserted using the conventional method with the navigation of three fluoroscopy views (Group A). The remaining 10 were inserted using the modified method with the navigation of two fluoroscopy views, including just the outlet and inlet views, without taking the lateral view, based on our theory and order of fluoroscopy (Group B). Following screw insertion, the accuracy of screw locations was evaluated using a computed tomography (CT) scan, and the duration of operations and radiation exposures were compared between the two surgery methods at the end of the study.

Results: In both groups, nine screws (90%) were located correctly, and one screw (10%) perforated the anterior wall of the first sacral vertebra. The mean±SD of the duration of radiation exposure in groups A and B was 6.1±1.0 min and 4.2±0.1 min, respectively (P=0.01). Moreover, the mean±SD of operation duration in group A was 45.7±5.8 min, but this value in group B was 35.5±4.5, which showed a significant decrease in operation duration (P=0.04).).

Conclusion: PSSF using a modified screw insertion method with just two fluoroscopy views not only had similar accuracy to conventional methods but also could decrease operation time and the following radiation exposure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11353148PMC
http://dx.doi.org/10.22038/ABJS.2024.77855.3589DOI Listing

Publication Analysis

Top Keywords

screw insertion
16
fluoroscopy views
16
modified screw
12
insertion method
12
percutaneous sacroiliac
8
screw
8
sacroiliac screw
8
screw fixation
8
method fluoroscopy
8
duration operations
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!