Objectives: Historically, fractures causing lumbopelvic dissociation have been managed with open lumbosacral fusion and instrumentation. Our aim was to evaluate outcomes and complications following surgical management of unstable transverse sacral fractures with percutaneous lumbopelvic fixation.

Methods: Design: Retrospective case series.

Setting: Academic Single Center, Level I Trauma Center. Patient Selection Criteria: Patients with lumbopelvic dissociation undergoing surgery. Outcome Measures and Comparisons: Patient demographics, mechanism of injury, ISS, associated injuries, radiographic classification (Roy-Camille), patient-reported outcomes (PROMIS PI, PF, D, and ODI), and complications were collected.

Results: 27 patients were enrolled with an average follow-up of 18.7 ± 17.6 months and age of 54.4 ± 25.1 years. All patients underwent lumbar pedicle screw and iliac screw placement. Sacral laminectomy was performed if the patient had a preoperative neurological deficit. Patients were counseled on instrumentation removal at 6-12 months. 67 % of patients sustained a fall, and 33 % were involved in an MVA. 52 % were Roy-Camille Type 2, and 32 % and 20 % were Types 1 and 3, respectively. The mean EBL was 261 ± 400 ml. 37 % required concurrent sacral laminectomy. There were no intraoperative complications and four postoperative complications, including surgical site infection, rod dislodgment, and deep venous thrombosis. 63 % underwent removal of instrumentation after fracture healing. ODI scores significantly improved from 6 weeks post-op (35.5 ± 4.5) to one-year follow-up (18.3 ± 9.6, p = 0.005), two-year follow-up (20.3 ± 10.0, p = 0.03), and final follow-up (16.4 ± 8.8, p = 0.002). Statistically significant improvements were observed in the PROMIS PI, PF, and D domains (p < 0.05).

Conclusion: Our study demonstrates that lumbopelvic instrumentation leads to successful management of unstable transverse sacral fractures, with improvement in PRO. The combination of percutaneous instrumentation without arthrodesis did not result in any fracture non-union.

Level Of Evidence: Level IV.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2024.111825DOI Listing

Publication Analysis

Top Keywords

management unstable
12
unstable transverse
12
transverse sacral
12
sacral fractures
12
percutaneous lumbopelvic
8
lumbopelvic dissociation
8
sacral laminectomy
8
sacral
5
instrumentation
5
patients
5

Similar Publications

Aims: Understanding the response of herbaceous plants to habitat changes and the mechanisms of vegetation succession is crucial to the theoretical foundation of the conservation of local vegetation.

Methods: Plots were established at elevations of 1900-2200m, 2200-2500m, and 2500-2800m on both shady and sunny slopes. Four statistical methods 2×2 contingency table χ-test, Spearman's rank correlation coefficient, AC joint coefficient, 17 and Ochiai Index, were employed to analyze the species composition and interspecific associations within each elevation band and aspect.

View Article and Find Full Text PDF

A new risk assessment model of venous thromboembolism by considering fuzzy population.

BMC Med Inform Decis Mak

December 2024

Department of Respiration, Peking Union Medical College Hospital, No.1, Shuaifuyuan, Dongcheng District, Beijing, 100730, China.

Background: Inpatients with high risk of venous thromboembolism (VTE) usually face serious threats to their health and economic conditions. Many studies using machine learning (ML) models to predict VTE risk overlook the impact of class-imbalance problem due to the low incidence rate of VTE, resulting in inferior and unstable model performance, which hinders their ability to replace the Padua model, a widely used linear weighted model in clinic. Our study aims to develop a new VTE risk assessment model suitable for Chinese medical inpatients.

View Article and Find Full Text PDF

Spontaneous liver bleeding is a rare but life-threatening complication of hepatocellular carcinoma (HCC). The optimal management strategy for this condition remains a topic of ongoing debate. We present the case of a 74-year-old man with cirrhosis and hemorrhagic shock resulting from the spontaneous rupture of HCC.

View Article and Find Full Text PDF

Development of a Self-Deploying Extra-Aortic Compression Device for Medium-Term Hemodynamic Stabilization: A Feasibility Study.

Adv Sci (Weinh)

December 2024

Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE), UNSW Sydney, Kensington Campus, Sydney, NSW, 2052, Australia.

Hemodynamic stabilization is crucial in managing acute cardiac events, where compromised blood flow can lead to severe complications and increased mortality. Conditions like decompensated heart failure (HF) and cardiogenic shock require rapid and effective hemodynamic support. Current mechanical assistive devices, such as intra-aortic balloon pumps (IABP) and extracorporeal membrane oxygenation (ECMO), offer temporary stabilization but are limited to short-term use due to risks associated with prolonged blood contact.

View Article and Find Full Text PDF

Background: Hemodynamically unstable pelvic ring fractures from high-energy trauma are critical injuries in trauma care, requiring urgent intervention and precise diagnostics. With ongoing advancements in trauma management, treatment strategies have evolved, with some techniques becoming obsolete as new ones emerge. This study aimed to evaluate changes and trends in treatment algorithms for these injuries over approximately 40 years.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!