A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and validation of a reversed-phase HPLC-UV method for simultaneous determination of levosulpiride and omeprazole in human plasma: Applicability of the method for evaluation of pharmacokinetic drug-drug interactions. | LitMetric

Levosulpiride and omeprazole are co-prescribed for gastrointestinal disorders associated with depression and anxiety. Objective of the study was to develop a sensitive, robust and simple method for simultaneous analysis of levosulpiride and omeprazole in human plasma and applicability of the method in determination of pharmacokinetics drug-drug interaction. In the presented study, a reversed-phase HPLC-UV method was developed for the simultaneous determination of levosulpiride and omeprazole using pantoprazole as the internal standard. Experimental conditions were optimized and the developed method was validated as per standard guidelines (USP and ICH). Furthermore, the developed method was applied for evaluation of pharmacokinetics drug-drug interaction between levosulpiride (50 mg) and omeprazole (40 mg) in healthy human volunteers. Sharpsil C8 column (4.6 × 250 mm, 5 μm), Ultisil C8 column (4.6 mm × 150 mm, 5 μm) and Agilent C18 column (4.6 × 250 mm, 5 μm) were evaluated as stationary phase. The best resolution was achieved with Agilent C18 (4.6 x 250 mm, 5 μm) column and was selected for further study. The mobile phase consisted of a mixture of acetonitrile and phosphate buffer (pH 7.2) in 60:40 by volume, and was pumped at a flow rate of 1 mL/min. Detector wavelength was set at 280 nm. Levosulpiride and omeprazole were extracted from human plasma with ethyl acetate and dichloromethane (4:1, v/v). The calibration curves for both levosulpiride (5-150 ng/mL) and omeprazole (10-1500 ng/mL) were linear. The lower limit of quantification and limit of detection for levosulpiride were 5 and 2 ng/mL, while for omeprazole these were 10 and 3 ng/mL, respectively. Pharmacokinetics analysis showed that co-administration of omeprazole increased the AUC and Cmax of levosulpiride, while the clearance was reduced. Both the changes were insignificant. Similarly, no significant change in the pharmacokinetic parameters of omeprazole was observed with co-administration of levosulpiride.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11361584PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0309453PLOS

Publication Analysis

Top Keywords

levosulpiride omeprazole
24
human plasma
12
250 μm
12
levosulpiride
10
omeprazole
10
reversed-phase hplc-uv
8
hplc-uv method
8
method simultaneous
8
simultaneous determination
8
determination levosulpiride
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!