Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Non-invasive monitoring of glucose levels in tears and saliva is crucial for diagnosing and predicting various illnesses, such as diabetic nephropathy. However, the capability of the current glucose detection methods to identify small amounts of glucose with a high sensitivity remains a significant obstacle. This study proposes a simple, visual technique for sensitively detecting glucose levels from tears and saliva using glucose oxidase (GOx) to catalyze glucose and pistol-like DNAzyme (PLDz) to enhance the signal. In particular, the β-D-glucose present in the samples serves as the initial molecule that GOx identifies and catalyzes to generate gluconic acid and hydrogen peroxide (HO). The HO induces the self-cleavage of PLDz, activating the "part b" sequence. This activation initiates catalytic hairpin assembly (CHA) and releases the DNAzyme section in the H1 probe. The DNAzyme acts as a peroxidase analog, facilitating the catalysis of the 3,3',5,5'-tetramethylbenzidine (TMB)-hydrogen peroxide (HO) system and resulting in color changes. The proposed method exhibits a broad detection range of six orders of magnitude and a low limit of 0.32 μM for glucose detection. Furthermore, the proposed method was highly effective in detecting glucose in saliva and tears, suggesting that it could potentially diagnose hyperglycemia-related disorders in clinical environments.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s12010-024-05046-7 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!