Background: We compared ultra-high resolution (UHR), standard resolution (SR), and virtual non-calcium (VNCa) reconstruction for coronary artery stenosis evaluation using photon-counting computed tomography (PC-CT).

Methods: One vessel phantom (4-mm diameter) containing solid calcified lesions with 25% and 50% stenoses inside a thorax phantom with motion simulation underwent PC-CT using UHR (0.2-mm slice thickness) and SR (0.6-mm slice thickness) at heart rates of 60 beats per minute (bpm), 80 bpm, and 100 bpm. A paired t-test or Wilcoxon test with Bonferroni correction was used.

Results: For 50% stenosis, differences in percent mean diameter stenosis between UHR and SR at 60 bpm (51.0 vs 60.3), 80 bpm (51.7 vs 59.6), and 100 bpm (53.7 vs 59.0) (p ≤ 0.011), as well as between VNCa and SR at 60 bpm (50.6 vs 60.3), 80 bpm (51.5 vs 59.6), and 100 bpm (53.7 vs 59.0) were significant (p ≤ 0.011), while differences between UHR and VNCa at all heart rates (p ≥ 0.327) were not significant. For 25% stenosis, differences between UHR and SR at 60 bpm (28.0 vs 33.7), 80 bpm (28.4 vs 34.3), and VNCa vs SR at 60 bpm (29.1 vs 33.7) were significant (p ≤ 0.015), while differences for UHR vs SR at 100 bpm (29.9 vs 34.0), as well as for VNCa vs SR at 80 bpm (30.7 vs 34.3) and 100 bpm (33.1 vs 34.0) were not significant (p ≥ 0.028).

Conclusion: Stenosis quantification accuracy with PC-CT improved using either UHR acquisition or VNCa reconstruction.

Relevance Statement: PC-CT offers to scan with UHR mode and the reconstruction of VNCa images both of them could provide improved coronary stenosis quantification at increased heart rates, allowing a more accurate stenosis grading at low and high heart rates compared to SR.

Key Points: Evaluation of coronary stenosis with conventional CT is challenging at high heart rates. PC-CT allows for scanning with ECG-gated UHR and SR modes. UHR and VNCa images were compared in a dynamic phantom. UHR improves stenosis quantification up to 100 bpm. VNCa reconstruction improves stenosis evaluation up to 80 bpm.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11362394PMC
http://dx.doi.org/10.1186/s41747-024-00482-wDOI Listing

Publication Analysis

Top Keywords

heart rates
20
stenosis evaluation
12
differences uhr
12
stenosis quantification
12
stenosis
11
uhr
11
vnca
9
ultra-high resolution
8
resolution virtual
8
virtual non-calcium
8

Similar Publications

Assessing modified HEART scores with high-sensitivity troponin for low-risk chest pain in the emergency department.

Intern Emerg Med

December 2024

Department of Emergency Medicine, JPS Health Network, 1500 S. Main St., Fort Worth, TX, 76104, USA.

The accuracy of using HEART (history, electrocardiogram, age, risk factors, and troponin) scores with high-sensitivity cardiac troponin (hs-cTn) to risk stratify emergency department (ED) chest pain patients remains uncertain. We aim to compare the performance accuracy of determining major adverse cardiac event (MACE) among three modified HEART (mHEART) scores with the use of hs-cTn to risk stratify ED chest pain patients. This retrospective single-center observational study included ED patients with suspected acute coronary syndrome who had HEAR scores calculated and at least one hs-cTnI result.

View Article and Find Full Text PDF

For end-stage renal disease (ESRD) patients requiring hemodialysis, reliable vascular access is crucial, especially when conventional supradiaphragmatic options are exhausted. This study reviews the technical aspects, clinical outcomes, and complications of translumbar and transhepatic tunneled dialysis catheter (TDC) placements. These alternative infradiaphragmatic approaches provide essential hemodialysis access for patients with central venous occlusions.

View Article and Find Full Text PDF

No FDA-approved medications for methamphetamine (MA) use disorder (MUD) are available. Suvorexant (SUVO), a dual orexin receptor antagonist that is FDA approved for insomnia treatment, reduces MA self-administration and MA-induced reinstatement responding in preclinical studies. SUVO may also reduce MA use by targeting substance use risk factors, including insomnia, stress, cue reactivity, and craving.

View Article and Find Full Text PDF

Background: Noninferiority of omitting intraoperative defibrillation threshold (DFT) testing has been documented for transvenous implantable cardioverter defibrillators (ICD) whereas data for the subcutaneous-ICD (S-ICD) regarding the need for DFT testing, especially during S-ICD generator replacement, is not available.

Methods: A total of 112 consecutive patients who underwent S-ICD generator replacement and routine testing were included in this retrospective single-center study and analyzed regarding the outcome of intraoperative DFT.

Results: The majority of patients (87.

View Article and Find Full Text PDF

Study Objectives: Isolated REM sleep behavior disorder (iRBD) is recognized as a prodromal stage of alpha-synucleinopathies. Predicting phenoconversion in iRBD patients remains a key challenge. We aimed to investigate whether event-related potentials (ERPs) recorded during visuospatial attention task can serve as predictors of phenoconversion in iRBD patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!