Prcis: Long-term success was achievable after GATT. GATT performed at early stage of glaucoma had better surgery outcomes. Trabeculoplasty may compromise surgery success.
Purpose: To evaluate the long-term effectiveness of prolene suture gonioscopy-assisted transluminal trabeculotomy (GATT) and identify factors that may affect surgical outcomes.
Patients And Methods: This is a retrospective cohort study of adult patients with prolene suture GATT performed by a single surgeon at 1 medical center.
Results: Of the 145 eyes from 124 patients studied, intraocular pressure was reduced from 22.1±7.8 to 15.1±3.2 and 15.1±3.5 mm Hg, and the number of glaucoma medications was reduced from 3.2±1.1 to 1.3±1.4 and 1.4±1.5 at postoperative years 3 and 4, respectively. Ninety-three and 71 eyes completed a 3- and 4-year follow-up, with 44% of the eyes at year 4 remaining medication free. Compared with eyes with combined GATT/cataract extraction (CE), eyes with GATT alone had significantly more preoperative medications and a higher reoperation rate (31% vs. 16.5%). Eyes with prior trabeculoplasty had a higher reoperation rate (28.8%) than those without (16.1%). Kaplan-Meier survival analysis revealed that GATT/CE eyes without trabeculoplasty had a longer median time to failure (48 mo) than GATT/CE eyes with trabeculoplasty (18 mo), and GATT eyes with or without trabeculoplasty (9 and 12 mo, respectively).
Conclusion: Prolene suture GATT successfully reduced IOP. Eyes with more preoperative medications responded less well to GATT. Prior laser trabeculoplasty was associated with poorer outcomes. Further study is needed to verify these findings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/IJG.0000000000002417 | DOI Listing |
Retina
February 2025
Department of Ophthalmology, Liyang Hospital of Chinese Medicine, Liyang, China.
Purpose: To describe a custom bent 27-gauge needle-guided suture snare technique for scleral fixation of posterior chamber intraocular lenses (PCIOL).
Methods: An 8-0 polypropylene suture was threaded into the lumen of a custom bent 27-gauge needle, and the needle tip was advanced into the eye from the intraocular lens (IOL) fixation point. The suture was threaded through the posterior limbal incision inside the IOL haptic loop and pulled out.
Eur J Ophthalmol
January 2025
Department of Ophthalmology, King's College Hospital, London, UK.
A 42 year old Afro-Caribbean man underwent Baerveldt Glaucoma Implant (BGI) surgery for silicone oil induced glaucoma. Three months following initial surgery, the 3-0 prolene ripcord suture was removed. Anterior segment OCT demonstrates the position of the intracameral portion of the tube before and after the 3/0 prolene stent suture (PSS) removal.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Translational Medical Sciences, University of Campania L. Vanvitelli, 80131 Naples, Italy.
A tracheoesophageal fistula (TEF) represents a condition characterized by abnormal communication between the gastrointestinal tract and the airways. Although the current gold-standard treatment is surgery, pre-existing clinical conditions may represent contraindications. We therefore propose a bronchoscopic approach through rigid bronchoscopy without tracheostomy for total repair in patients suffering from benign tracheoesophageal fistulas.
View Article and Find Full Text PDFCureus
December 2024
Ophthalmology, Sankara Eye Hospital, Anand, IND.
This study details two cases of traumatic cataracts with a history of blunt trauma. Both presented with progressive vision loss, mydriasis, and zonular dialysis. The surgical intervention involved complete cataractous lens removal, anterior vitrectomy, iris cerclage with 10-0 prolene sutures, and retropupillary iris-claw lens fixation.
View Article and Find Full Text PDFBiomed Mater
January 2025
Dagestan State Medical University, 367000 Makhachkala, Dagestan, Russia.
Suture-associated surgical site infection (SSI) causes bacterial pathogens to colonize on the suture surface that are highly resistant to antibiotic treatment. Conventional suture materials used in surgical practice are causing complications such as infection and chronic inflammation. Surgical suture materials with antibacterial coatings are widely used in surgical practice.