In modern oncology, despite the efficacy of chemotherapy, there is a risk of cardiotoxicity resulting in heart failure. This necessitates early diagnosis to prevent complications and improve prognosis. The study is aimed at analysing the abilities of speckle-tracking echocardiography as a modern tool in detecting cardiotoxicity in the early stages. This non-invasive method allows evaluating myocardial strain and its contractility. During a thorough analysis and extensive review of the scientific literature, it was found that the speckle-tracking echocardiography technique demonstrates an exceptionally high sensitivity to detecting early signs of cardiotoxicity, significantly outpacing conventional echocardiography methods in this aspect. This advantage makes it an invaluable tool in the early detection of potentially dangerous changes in the myocardium, which is especially important for patients at risk of developing cardiotoxic reactions as a result of chemotherapy. Speckle-tracking echocardiography has a unique ability to identify even the slightest local abnormalities in the structure and function of the myocardium, significantly before any clinical symptoms become apparent, thereby allowing doctors to take preventive measures at the earliest stages. This outstanding diagnostic ability is supported by an extensive body of scientific research and publications that unequivocally confirm the effectiveness of speckle-tracking echocardiography as an advanced tool for the early diagnosis of cardiotoxic changes. Thus, the timely application of this technique can significantly reduce the risks to the cardiac health of patients and contribute to more effective treatment of oncological diseases. Speckle-tracking echocardiography serves as an important tool in the early detection of cardiotoxicity in patients undergoing chemotherapy, allowing clinicians to timely adapt treatment protocols and prevent the development of serious cardiovascular complications, thereby improving the prognosis and quality of life of cancer patients.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00015385.2024.2396762DOI Listing

Publication Analysis

Top Keywords

speckle-tracking echocardiography
24
tool early
16
early detection
12
detection cardiotoxicity
8
cancer patients
8
early diagnosis
8
early
7
speckle-tracking
6
echocardiography
6
tool
5

Similar Publications

Objectives: Supra-normal left ventricular ejection fraction (snLVEF) represents a heterogeneous group with distinct prognoses. Left atrial (LA) strain, measured by speckle tracking echocardiography (STE), is a validated prognostic indicator. This study aimed to evaluate LA and left ventricular (LV) mechanical strains in hypertensive patients with snLVEF.

View Article and Find Full Text PDF

Aims: The study was designed to investigate the characteristics of atrial ventricular coupling and left atrial (LA) function impairment in patients with Fabry disease (FD), especially those in the early stages of the condition.

Methods: A total of 65 patients with Fabry disease who completed echocardiographic examinations from January 2018 to May 2024 were ultimately included. Among them, 25 patients with FD did not have left ventricular (LV) hypertrophy (LVH).

View Article and Find Full Text PDF

Background: The relationship between premature ventricular contractions (PVC) and right ventricular (RV) function is not widely known. Left ventricular (LV) dysfunction due to PVC is known as PVC-induced cardiomyopathy (PIC) and suppressing the PVC substrate would improve LV function. The effect of PVC ablation on changes in RV function in patients with subtle RV subclinical dysfunction remains unknown.

View Article and Find Full Text PDF

Evaluating cardiac performance in beagle dogs: Transesophageal echocardiography and myocardial work assessment.

Heliyon

January 2025

Department of Ultrasound Medicine, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, 210008, People's Republic of China.

Objectives: This study aimed to establish standard transesophageal echocardiographic (TEE) measurements of left ventricular (LV) morphology, function, and myocardial work parameters in healthy Beagle dogs using pressure-strain loops (PSL). Additionally, it sought to standardize optimal TEE imaging techniques and explore the potiential application of myocardial work analyis in veterinary medicine.

Methods: Thirty-seven healthy male Beagle dogs were anesthetized, intubated, and mechanically ventilated for TEE examinations.

View Article and Find Full Text PDF

Prognostic Value of LV Global Longitudinal Strain by 2D and 3D Speckle-Tracking Echocardiography in Patients With HFpEF.

Circ Cardiovasc Imaging

January 2025

Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China (Y. Lin, M.X., L.Z., Y.Z., P.Z., X.C., M.J., L.G., Q.H., Z.W., Y.Y., Y. Li).

Background: In patients with heart failure with preserved ejection fraction (HFpEF), the impact of type 2 diabetes (T2D) on left ventricular global longitudinal strain (LV GLS) and its prognostic implications remains unclear. We aimed to evaluate LV function using two-dimensional (2D) and three-dimensional (3D) speckle-tracking echocardiography in patients with HFpEF with and without T2D, and to investigate its prognostic significance.

Methods: A total of 335 patients with HFpEF were prospectively enrolled for echocardiographic evaluation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!