Magnetic flux leakage (MFL) inspection employs leakage magnetic fields to effectively detect and locate pipeline defects. The spacing between magnetic poles significantly affects the leakage magnetic field strength. While most detectors typically opt for moderate pole spacing for routine detection, this study investigates the propagation characteristics of MFL signals at small pole spacings (under specimen oversaturated magnetization) and their impact on MFL detection. Through finite element simulation and experiments, it reveals a new signal phenomenon in the radial MFL signal at small pole spacings, the double peak-valley (DPV) phenomenon, characterized by outer and inner peaks and valleys. Theoretical analysis based on the simulation results elucidates the mechanisms for this DPV phenomenon. Based on this, the impact of defect size, pipe wall thickness, and magnetic pole and rigid brush height on MFL signals under small magnetic pole spacings is examined. It is demonstrated that, under a smaller magnetic pole spacing, a potent background magnetic field manifests in the air above the defect. This DPV phenomenon is generated by the magnetic diffusion and compression interactions between the background and defect leakage magnetic fields. Notably, the intensity of the background magnetic field can be mitigated by reducing the height of the rigid brush. In contrast, the pipe wall thickness and magnetic pole height exhibit a negligible influence on the DPV phenomenon. The emergence of the DPV precipitates a reduction in the peak-to-valley difference within the MFL signal, constricting the depth range of detectable defects. However, the presence of DPV increases the identification of defects with smaller opening sizes. These findings reveal the characterization of the MFL signal under small pole spacing, offering a preliminary study on identifying specific defects using unconventional signals. This study provides valuable guidance for MFL detection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11359129PMC
http://dx.doi.org/10.3390/s24165195DOI Listing

Publication Analysis

Top Keywords

pole spacing
16
dpv phenomenon
16
magnetic pole
16
magnetic
13
leakage magnetic
12
magnetic field
12
small pole
12
pole spacings
12
mfl signal
12
pole
9

Similar Publications

Small piezoelectric wind-induced vibration energy harvesting systems have been widely studied to provide long-term sustainable green energy for a large number of wireless sensor network nodes. Piezoelectric materials are commonly utilized as transducers because of their ability to produce high output power density and their simple structure, but they are prone to material fracture under large deformation conditions. This paper proposes a magnetic boundary modulated stepped beam wind energy harvesting system.

View Article and Find Full Text PDF

Analysis of the traction forces of two adjacent linear induction motors.

Sci Rep

November 2024

State Key Laboratory of Rail Transit Vehicle System, Southwest Jiaotong University, Chengdu, 610031, China.

Linear induction motors (LIMs) are positioned head-to-tail in medium and low-speed maglev (MLSM) trains, and the interaction due to small spacing between two LIMs is not yet clear. In this work, based on the 2D electromagnetic field theory, the vector magnetic potential (VMP) of each region was solved, and the traction forces of two adjacent LIMs were derived. Subsequently, the correctness of the theoretical model was verified by simulation.

View Article and Find Full Text PDF

Magnetic flux leakage (MFL) inspection employs leakage magnetic fields to effectively detect and locate pipeline defects. The spacing between magnetic poles significantly affects the leakage magnetic field strength. While most detectors typically opt for moderate pole spacing for routine detection, this study investigates the propagation characteristics of MFL signals at small pole spacings (under specimen oversaturated magnetization) and their impact on MFL detection.

View Article and Find Full Text PDF

Soft pneumatic actuators (SPAs) are commonly used in various applications because of their structural compliance, low cost, ease of manufacture, high adaptability, and safe human-robot interaction. The traditional approach for achieving proportional control of soft pneumatic robots requires the use of industrial proportional valves or syringe drivers, which are not only rigid and bulky but also hard to be integrated into the body of soft robots. In our previous research, we developed a Magnetorheological elastomer (MRE)-based soft valve that showed advantages for controlling SPAs due to its compliance, compactness, robustness, and compatibility for continuous pressure modulation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!